Error code

Error type

Description

Solution

5102, "Missing
data from
camera: Time
since last frame
[s] "

Hardware
error.

Can resolve
itself.

See error

5101, "Unable

to connect to camera."
on page 17

.

5103, "Lost
connection to
camera: Time
since last frame
[s] "

Hardware
error.

Can resolve
itself.

See error

5101, "Unable

to connect to camera."
on page 17

.

9000,
"Diagnostics
monitoring: Stale
error (Expected
diagnostics
messages
missing)"

Hardware
error.

Can resolve
itself.

The robot computer is
expecting diagnostics
messages that have not
arrived in time. The
error should describe
which diagnostics
message is missing.

Depending on the description in the
error code, check various fields in

Hardware Health

to locate the exact

error. Browse the troubleshooting
guides on the Distributor site to see if
any of them describe the situation
you are experiencing. If not, contact
Technical Support.

10101,

<actionname>

aborted -

<current_
action_name>

failed to start
(

<status>

)"

Mission error.

Requires
interaction.

An action in your
mission cannot be
completed. An
exception has been
thrown that was not
caught in your mission.
The reason for the
failure is described in
the error code text.

Review the mission you tried to
execute. Verify that the chosen
actions are executable, such as
ensuring that positions are part of the
active map. Consider adding a
Try/Catch action to provide the robot
with an alternative action if the
attempted action failed. This will
prevent the error from appearing in
future cases.

Summary of Contents for MiR Series

Page 1: ...Error codes and solutions Troubleshooting guide en Date 07 2020 Revision 1 1 Valid for All MiR robots...

Page 2: ...sts you have to address the issue by determining the cause of the issue Often the issue is caused by faulty cable connections or broken components Before inspecting the robot s internal parts it is a...

Page 3: ...roubleshoot your robot effectively you may need to investigate the internal or external parts while the robot is turned on You will be exposed to electrical and mechanical hazards Only connect the bat...

Page 4: ...upport Before creating a support request it is highly recommended to update to the latest recommended software as this may resolve the issue It will also enable your robot to generate a more detailed...

Page 5: ...can diagnose and solve the issue correctly attach an error log retrieved from the robot It is important that the error log is generated as described in the guide How to generate an error log found on...

Page 6: ...sary as this may damage the connection between the wire and connector When checking a wire it should only be able to move 0 5 mm from its original position at most If the cable and connector are secur...

Page 7: ...pdate to the latest version try to roll back to a functioning software version and report the issue to Technical Support 201 Free Memory is VERY low Hardware error Can resolve itself An issue has occu...

Page 8: ...ort on page 4 401 Very low free space on harddrive Hardware error Requires interaction The hard drive memory is almost filled up Begin by deleting old backups stored on the robot this can be done thro...

Page 9: ...ributor site 601 Teensy Gyroscope data timed out Last Gyroscope message received seconds d seconds ago Hardware error Can resolve itself The MiR board is not receiving data from the gyroscope Try rebo...

Page 10: ...not updated to the latest software it is recommended to update your robot this may solve the issue If the issue occurred after a software update to the latest version try to roll back to a functioning...

Page 11: ...R board Wait at least ten minutes to give the robot time to finish uploading Otherwise if the uploading time seems excessive cancel the upload and try to update the software again 701 MIR100 200 Motor...

Page 12: ...e power to the motor controller For the 24V supply wire 041 begins the connection from the controller to the battery via relays and fuses For the 5V power supply wire 071 begins the connection Refer t...

Page 13: ...ION_FAILED_ NO_SCANNER_DATA on page 25 803 SICK S300 Got xx failed transmissions in the last xx seconds Hardware error Can resolve itself See error 10202 E_ LOCALIZATION_FAILED_ NO_SCANNER_DATA on pag...

Page 14: ...lugged in and that there are no obvious signs of damage If no faults are found try hooking up the camera to your computer via the USB cable that connects to the robot computer If you are unable to con...

Page 15: ...in error 901 Camera OpenNI Waiting for connection is taking longer than expected on the previous page 911 Camera realsense R200 D435 Unable to detect camera with serial xxxx yyyy zzzz etc however xx o...

Page 16: ...etected cameras to the last serial number reported in the error Select Save changes If the error does not disappear within a minute try rebooting the robot 911 Camera realsense R200 D435 Unable to det...

Page 17: ...ety PLC If you are experiencing errors in the safety system we cannot troubleshoot programs with custom modifications Download a new standard configuration file from the robot interface and upload it...

Page 18: ...bot computer Wait approximately ten minutes to see if the computers begin to sync If not reboot the robot If the issue still persists you can manually sync the robot and hook under System Settings Tim...

Page 19: ...200 Operating guide You can also test the brake by signing into the robot and going to Hook Manual control and selecting Activate and Deactivate brake 5302 Hook brake failed Timeout Hardware error Req...

Page 20: ...page 3 5302 Hook brake release failed Fault flag active Hardware error Requires interaction The brake was expected to move a certain number of encoder ticks for successful release of the brake but a...

Page 21: ...ue to the duty cycle of the brake motor See the solution description in error Safety on page 3 5310 Hook brake Initialization failed Hardware error Can resolve itself Initialization of the brake motor...

Page 22: ...ed to encoder cable fault Hardware error Can resolve itself The connection between the hook computer and the hook encoders is faulty Remove the cover from MiRHook and check the wiring from the encoder...

Page 23: ...ould like to move the robot to is inside a forbidden area If the robot must go to that position review your active map and remove the forbidden area move the position to an accessible area for the rob...

Page 24: ...would like the robot to move to is blocked by an obstacle Check that the area you would like to move the robot to is clear Consider adding a Try Catch action to provide the robot with an alternative...

Page 25: ...ly localize itself at first but as soon as it begins to move the robot in the map moves either faster or slower than it does in reality resulting in the red scanner lines being misaligned with the wal...

Page 26: ...Advanced settings 10702 motor stall detected Environmental error Requires interaction Hardware error Requires interaction See error Safety on page 3 10701 Left motor encoder signal missing Hardware er...

Page 27: ...cision docking Hardware error Can resolve itself The robot computer has lost connection to the controller for the precision docking locking mechanism Check that the precision docking controller Raspbe...

Page 28: ...are update to the latest version try to roll back to a functioning software version and report the issue to Technical Support 201 Free Memory is VERY low Hardware error Can resolve itself An issue has...

Page 29: ...rror Can resolve itself The hard drive memory is almost filled up Begin by deleting old backups stored on the robot this can be done through the robot interface under System Backups If the issue persi...

Page 30: ...solve the issue If the issue occurred after a software update to the latest version try to roll back to a functioning software version and report the issue to Technical Support 801 SICK Microscan 3 Lo...

Page 31: ...ts refer to the solution in error 5101 Unable to connect to camera on page 39 911 Camera realsense D435 Unable to detect camera with serial xxxx yyyy zzzz etc however xx other cameras are connected wi...

Page 32: ...n a minute try rebooting the robot 911 Camera realsense D435 Unable to detect camera with serial xxxx yyyy zzzz etc and no other cameras available Hardware error Requires interaction See error 5101 Un...

Page 33: ...uires interaction You have modified the SICK program on the safety PLC If you are experiencing errors in the safety system we cannot troubleshoot programs with custom modifications Refer to the soluti...

Page 34: ...error Can resolve itself The current delivered to the top application power interface is outside the limits max 20 A Inspect your top application Contact your top application distributor for assistanc...

Page 35: ...e itself The voltage delivered from the battery is outside the limits Inspect the cable from the battery to the power board If no faults are found replace the battery 2110 Voltage monitor VBat_ Fuse H...

Page 36: ...Figure 1 8 that leads from the power board to the top application interface if no faults are found in the cable 2116 Voltage monitor 5V0 Hardware error Can resolve itself The 5 V power supply is faul...

Page 37: ...Hardware error Can resolve itself The 12 V power supply is faulty See the solution in 2111 Voltage monitor 12V on page 35 2121 Voltage monitor 5V_Inp Hardware error Can resolve itself The 5 V power su...

Page 38: ...ntroller carrier board 2210 Can Bus Error Proximity sensor Light controller Left side Front Hardware error Can resolve itself See error above 2210 Can Bus Error Proximity sensor Light controller Left...

Page 39: ...board is faulty See the solution description for error 2203 Can Bus Error Right MotorController on page 37 5101 Unable to connect to camera Hardware error Can resolve itself The robot computer is not...

Page 40: ...sing Depending on the description in the error code check various fields in Hardware Health to locate the exact error Browse the troubleshooting guides on the Distributor site to see if any of them de...

Page 41: ...error Requires interaction The position you would like to move the robot to is inside an obstacle defined in your active map Review your active map and check that dynamic obstacles objects in the are...

Page 42: ...ION_ FAILED Environmental error Requires interaction The robot is not able to correctly localize itself When looking in the active map in the robot interface if the red scanner lines do not align enou...

Page 43: ...s to the safety PLC CAB 012 and CAB 013 from the power board to the front and rear scanners CAB 010 from the PLC to the front scanner and CAB 011 from the front to the rear scanner CAB 074 from the po...

Page 44: ...500 MiR1000 10702 Left motor stall detected Environmental error Requires interaction Hardware error Requires interaction There is a high power output to the left motor but the robot is not moving This...

Page 45: ...nt If this cable is fine you will either need to replace the left side bogie or the motor controller carrier board Refer to the how to guide How to replace the bogie with motor on MiR500 MiR1000 or Ho...

Page 46: ...ing guide en 07 2020 v 1 1 Copyright 2019 2020 Mobile IndustrialRobots A S 46 Reference images MiR100 MiR200 Figure 1 1 Power light on MiR board The top left USB connector connects the board to the ro...

Page 47: ...ight 2019 2020 Mobile IndustrialRobots A S 47 Figure 1 2 Robot computer USB connections Label no Description Label no Description 1 Connects to front laser scanner 2 Connects to rear laser scanner 3 C...

Page 48: ...7 2020 v 1 1 Copyright 2019 2020 Mobile IndustrialRobots A S 48 Figure 1 3 Router and its inputs Label no Description Label no Description 1 Connects to the robot computer 2 Connects to safety PLC 3 C...

Page 49: ...Troubleshooting guide en 07 2020 v 1 1 Copyright 2019 2020 Mobile IndustrialRobots A S 49 Figure 1 4 Motor controller LED...

Page 50: ...Hook 100 MiR Hook 200 Figure 1 5 MiR Hook 100 MiR Hook 200 internal components Label no Description Label no Description 1 Fuse box 2 DC DC USB 3 Top application power interface 4 Hook computer 5 Enc...

Page 51: ...Troubleshooting guide en 07 2020 v 1 1 Copyright 2019 2020 Mobile IndustrialRobots A S 51 MiR500 MiR1000 Figure 1 6 CAB 30 from the battery...

Page 52: ...2 Figure 1 7 Front and rear laser scanner respectively The black cable are the power cables CAB 012 and CAB 013 and the blue cable are the connection cables CAB 010 and CAB 011 The rear scanner connec...

Page 53: ...tery charger connection 2 CAB 038 3 CAB 039 4 CAB 074 Safety PLC power 5 CAB 012 Front laser scanner power 6 CAB 013 Rear laser scanner power 7 CAB 018 Router and computer power 8 CAB 071 Speaker 9 Au...

Page 54: ...able connection Label no Cable connection 13 CAB 040 Top application GPIO 14 CAB 067 On Off swith power 15 CAB 014 CAN bus connection to motor controller carrier board 16 CAB 066 Pendant 17 Unused 18...

Page 55: ...3 Unused 4 CAB 052 Left motor power 5 CAB 022 Left Hall sensor 6 CAB 025 LEFT Left feedback 7 CAB 016 Protective stop 8 CAB 014 CAN bus connection to power board 9 CAB 023 Left motor encoder 10 CAB 01...

Page 56: ...2020 Mobile IndustrialRobots A S 56 Document history Version Date Description 1 0 2019 11 11 First edition 1 1 2020 07 23 Added description of error code types Added error 13000 Added errors 10711 an...

Reviews: