Troubleshooting guide (en) 07/2020 - v.1.1 ©Copyright 2019-2020: Mobile Industrial Robots A/S.
12
Error code
Error type
Description
Solution
710,
"MIR100/200
Motor
Controller:
Initialization
failed!"
Hardware
error.
Can resolve
itself.
The connection between
the motor controller and
the robot computer is
faulty.
Verify that power is delivered to the
motor controller. There is a power
LED light that will light green if both
the 5V and 24V power is delivered (see
). If either of these lights is
turned off, you will need to inspect the
cables supplying the power to the
motor controller. For the 24V supply,
wire 041 begins the connection from
the controller to the battery via relays
and fuses. For the 5V power supply,
wire 071 begins the connection. Refer
to the MiR100/MiR200 wiring diagram
found on the Distributor site.
If the motor controller is receiving
power, check the wires 085, 086 and
088 that connect from the motor
controller to the robot computer.
711,
"MIR100/200
Motor
Controller:
Unable to
connect to
motor
controller!"
Hardware
error.
Can resolve
itself.
See error
"MIR100/200 Motor
Controller: Initialization
failed!" above
.
712,
"MIR100/200
Motor
Controller: Lost
connection to
motor
controller!"
Hardware
error.
Can resolve
itself.
See error
"MIR100/200 Motor
Controller: Initialization
failed!" above
.