MobileView Network Switch Quick Reference

5.

Press 

Upgrade

 to start the process and follow the on screen 

prompts to complete. The switch will reboot upon completion 
of the upgrade process.

Reboot & Factory Default

The MVNS-3200 includes a special purpose button used to 
manually reset the switch if it becomes unresponsive. To reset, 
insert a blunt tipped, non-metal object like a toothpick into the hole 
above the word 

reboot

 on the front of the switch until the 

recessed button is activated. After 1 second, remove the object 
and the switch will reboot.

To restore the device to factory defaults, hold the button pressed 
for 10 seconds. Upon object removal the switch will reboot and be 
configured to factory default settings.

Status Indicators

The MVNS-3200 displays the system status with two LED and 
one relay output.

The fault relay is active under normal conditions. This ensures 
that remote systems monitoring the switch observe a fault 
condition when the switch is OFF. 

During the start up process the relay may change several times. 
Once the relay is in operational state, it will become stable. 

Installation

The MVNS-3200 incorporates an integral mounting flange with 
four (4) precut bolt holes. To mount the switch:

1.

Use the switch base as a template to mark and drill four (4) 
holes in the mounting surface.

2.

Using bolts, locking washers, and nuts, mount the switch to 
the vehicle surface.

Note:

If necessary, precut bolt holes may be widened to 
support up to ¼” diameter bolts.

Mounting

The MVNS-3200 is optimally designed for horizontal mounting to 
a flat and vibration resistant surface. Since it is a solid state device 
with no moving parts, the switch may be mounted in any 
orientation without effect on operational capabilities.

Caution:

The switch utilizes passive cooling through a network 

of fins along the bottom of the device. These fins rely on air 

movement to function. Do not mount the switch to surfaces that 
restrict air movement such as carpet.

Harness & Connections

The MVNS-3200 has a single harness with two connectors to 
attach field wires. The connector and pin schedule are as shown.

Caution:

When making connections to the switch or harness, 

ensure the vehicle power is off or disconnected.

Caution:

Power connections from the vehicle to the harness 

must use 16AWG capable of carrying up to a 7.5 amp load.

Caution:

Use 7.5A ATO replace fuse only.

The switch is designed to have main power and ground applied all 
the time without starting. The device will initiate startup only when 
the power control input is present and will shut down when the 
control signal is absent. 

Note:

Connect the switch power control input to a 12V output 
from the recorder that is ON when the recorder is 
running. This will ensure the switch is ON when the 
recorder is ON.

Note:

Refer to Electrical Specifications for acceptable power 
control input voltage values.

Input Voltage

The MVNS-3200 works within the following voltage ranges. 

Feature

Type

Use/Comment

Main Power

LED

Indicates power state
Red = Power Available
Red Blink = Booting
Green = Device ON

Fault

LED

Indicates fault state
Off = Normal

Amber = Fault

Fault

Relay

Indicates fault state

Active = Normal

Inactive = Fault

Switch

Color

Use

Field

X1.1

Red

Main PWR (+) Fused 7.5A

X2.1 & X2.4

X1.2 

Black

GND

X2.2 & X2.5

X1.3 

White 

PWR Control (+) 

X2.3 & X2.6

X1.4 

Brown 

Fault Relay (NC)

X3.1

X1.5 

Blue

Fault Relay (C)

X3.2

X1.6 

White 

Fault Relay (NO)

X3.3

Model

Input Voltage

Supported Range

Power Out

8-Port

12V/24V

Low = 9VDC, High = 32VDC

51W

16-Port

24V Only

Low = 16VDC, High = 32VDC

102W