Installing the MX-Overvoltage-Protection-Box-RJ45
1. Attach the box
Attach the MX-Overvoltage-Protection-Box-RJ45 at the mounting
position with the cable ports pointing downwards and open the
lid of the box (three screws).
2. Connect ground wire
Open the terminal screw (red circle in figure) using a regular
screw driver. Strip the insulation of the supplied or existing
ground wire for approx. 5 mm/0.2 in and push the wire through
the eight-wire plug in the center. Insert wire into terminal and
fasten terminal screw.
3. Attach the patch cable, close box
Remove both bayonet catches and the sealing plugs, insert MOBOTIX
patch cables into the cable ports and secure them using the
bayonet catches as shown.
Only use MOBOTIX patch cables
with integrated sealing ring!
Mount the cover back onto the box (torque 0.4 Nm).
Installing the MX-Overvoltage-Protection-Box-LSA
1. Attach the box
Attach the MX-Overvoltage-Protection-Box-LSA at the mounting
position with the cable ports pointing downwards and open the
lid of the box (three screws).
2. Connect ground wire
Open the terminal screw (red circle in figure) using a regular
screw driver. Strip the insulation of the supplied or existing ground
wire for approx. 5 mm/0.2 in and push the wire through the eight-
wire plug at the left. Insert wire into terminal and fasten terminal
screw.
3. Prepare the installation cable
Cut the installation cable to size, push it through the cable plug
5 to 7 mm in the center, strip the cable for at least 35 mm and
separate the individual wires of the cable into twisted pairs with
20 mm shielding. Wrap the shield mesh around the cable sheath
10 mm wide so that it can rest on the contact plate of the board.
The cable will be fastened with a cable tie later on.
4. Feed the cable into the box
In order to prevent humidity entering the box, the rubber sleeve
needs to be tight against the cable. Guide the supplied cable tie
through the two cable slots as shown and pull the cable tie tight
around the cable shield to provide proper strain relief.
5. Connect the cable wires
Use an
LSA PLUS wire insertion tool to insert the individual wires
into the LSA terminal. Decide on using either the EIA/TIA-568A
or B wiring standard as in the rest of the building. The color
code sticker in front of the LSA terminal shows both standards.
If no LSA PLUS tool is available, you can use a tool with inter-
changeable blades (LSA/Krone blade with setting “Low Impact”).
6. Attach the patch cable, close box
Remove right-hand bayonet catch and sealing plug, insert MOBOTIX
patch cable into the cable port and secure it using the bayonet
catch as shown.
Only use MOBOTIX patch cables with inte-
grated sealing ring!
Mount the cover back onto the box (torque 0.4 Nm).
~20 mm
~35 mm
~15 mm
~10 mm
Shield mesh
Cable
sheath
Pair shield
Technical Specifications MX-Overvoltage-Protection-Box
Normal Usage
Surge protection for MOBOTIX cameras with PoE
power supply
(PoE+ according to IEEE 802.3at up to 57 V)
Protection Against
Surges
Tested up to 4 kV on all wires of an attached cable
according to test standard EN 61000-4-5
Protection Class
IP66 (DIN EN 60529)
Protection Against
Mechanical Impact
IK08 (nach IEC 62262/EN 50102)
Operating Temperature
–30 to 60 °C/–22 to 140 °F (DIN EN 50125)
Strength of the Ground
Wire
1.5 to 2.5 mm
2
Drilling Template for VarioFlex Wall Mount with MX-Overvoltage-Protection-Box
80 mm/3.15 in
80
mm/3.15
in
75 mm/2.95 in
15
mm/
0.59
in
MX-Overvoltage-Protection-Box
VarioFlex Wall Mount