Preparations of installation:
Exhaust hood is equipment which sucks smoke and cooking fragrance. With a vent hood, your kitchen will be free
from oil particles that may produce bad odor
1.
Check the strength of wall on which the exhaust hood is
to be installed. Make sure the wall can sustain the weight/
load of the vent hood.
2.
The exhaust hood should be installed precisely over the
stove at a vertical distance of 65 - 75 cm from the stove
surface. Especially for incline/angle type the vertical
distance is 35
– 45 cm.
Installing the Cook Hood on The Wall
Exhaust hood must be installed perpendicularly to prevent the oil
from flowing to one side and dripping out of the vent hood.
Creating holes on the wall and methods for installing bracket
Notes:
-
Height / distance are 35 - 45 cm.
-
For CX 7712 L, we recommend installation for use with a stove without top cover.
-
Height / Distance C can be shortened in accordance with the ceiling height.
-
Make a vertical line on the wall to its highest point or to an appropriate height on the center part of
the area where the vent hood is to be installed
-
Make a horizontal line at H (cm) distance from the stove to mark the lowest limit for the vent hood.
-
Install bracket I on the wall just like in the above picture up to height A and mark the holes for fisher.
-
Install bracket II on the wall just like in the above picture up to height B and mark the holes for
fisher hole.
-
Install bracket III on the wall just like in the above picture up to height C and mark the holes for
fisher hole.
-
Drill the wall with a Ø 8 mm for fisher in all marked sections.
-
Insert the fishcer into the hole.
-
Install all brackets using the provided fischer screws
Model
A (cm)
B (cm)
C (cm)
CX 7712 L
25
39
39