7
CX 9150, CX 9330, and CX 9753
Preparations of installation:
The exhaust hood is equipment which vacuums the smoke and odor produced in cooking process. With an exhaust hood,
your kitchen will be free from oil particles which produces bad odor.
1.
Check the strength of wall on which the hood is to be installed. Make
sure the wall can sustain the weight / load of the hood.
2.
The hood should be installed precisely over the stove at a vertical
distance of 65 - 75 cm from the stove surface.
.
INSTALLING THE HOOD ON WALL
Creating holes on the wall and methods for installing bracket
Notes:
•
Height / distance are 65
– 75 cm, except for CX 9753 type where the height / distance is 35 – 40 cm.
•
For CX 9753, we recommend installation for use with a stove without the top cover.
•
Height / Distance C can be shortened in accordance to the ceiling height.
•
Make a vertical line on the wall to its highest point or to an appropriate height on the center part of the area where
the vent hood is to be installed
Model
A (cm)
B (cm)
C (cm)
CX 9753
37.5
39
39
CX 9330
34.5
20.5
49
CX 6330
34.5
20.5
49
CX 9150
34.5
20.5
49
CX 6150
34.5
20.5
49
Part 3: Installation
The hood must be installed in an upright position to prevent the oil from
flowing to one side and dripping out of the exhaust hood.