9
In this version, the vent hood sucks the smoke / cooking odor and filters it through an aluminum filter and carbon
filter. The filtered smoke is then reticulated into the room. This system is used if the premise renders it impossible to
install a ducting system
Several things which must be ensured when installing a vent hood with reticulating system:
1. Both carbon filter and aluminum filter must be used.
2. The position of both filters must be precise.
3. Circulation holes on the exhaust hood are not allowed to be closed
CX 7110 L, CX 7310 L, CX 9156, CX 9301, CX 9356, and CX 9701
Preparations of installation:
•
If you have a waste pipe outside, the exhaust hood can be connected using extraction duct (enamel, aluminum,
flexible pipe or a fire-resistant material with an inner diameter of 150 mm), see the following picture:
•
Before installation, switch off the unit and unplug the power cord from the power socket
•
Installation of the exhaust hood should be right on the top of the stove with a minimum distance of
65 cm and a height of maximum 75 cm from the surface of the stove
Installation (DUCTING / EXHAUST System):
•
Attention! Observe the warning in the instruction sheet concerning the operation of the
appliance when air is discharged from the room
Summary of Contents for Cesena Series