11
•
To ensure the durable operation of water heater, it is
recommended to regularly clean the internal tank and remove the
deposits in the electric heating element. Also, check the condition
of the magnesium anode (whether it is fully decomposed or not)
and, if necessary, replace it with a new one in case of full
decomposition. Tank cleaning frequency depends on the hardness
of the water in the usage location. Cleaning must be performed by
MODENA
technicians or authorized maintenance services.
•
This water heater is equipped with a thermal switch, which cuts off
the power supply of the heating element if the water is overheating
or no water in the heating element. If the water heater has been
connected to the power (electricity) source but the water is not
heated and the indicator does not light up, then the thermal switch
is “OFF”. To reset the water heater to the normal operating
condition, it is necessary to:
1.
De-energize the water heater; remove the plate of the front
cover (upside);
2.
Press the button that is located at the center of the thermal
switch (see the picture below);
3.
If the button is not pressed and there is no clicking, then you
should wait until the thermal switch cools down to the default
temperature.
WARNING!
Non-professionals technicians are not allowed to disassemble the
thermal switch to reset. Please contact
MODENA
professionals for
the appliance maintenance. Otherwise,
MODENA
will not take
responsibility if any accident happens because of the failed
maintenance procedure
Manual Reset Button