English
12
The information shown below aims to help with the identification and correction of any anomalies
and malfunctions which could occur during use. Some of these problems can be resolved by the
user. For the others, precise skill is required and they must therefore only be carried out by
qualified staff.
Problem
Causes
Solutions
Fail to ignite
Forget to open gas valve
Turn on gas valve
Hose folded or flattened
Line up or replace the hose
Air inside gas hose
Continuous ignition
Valve or nozzle blocked
Consult to Service Center
Ignition electrode dirty
Clean with soft dry cloth
Gas used out
Replace gas bottle
Ignition operation too fast
Ignite slowly and lightly
Gas leakage
(Smell of gas)
Gas hose not well connected
Properly connect gas hose
Broken gas hose
Replace gas hose
Abnormal flame
Too low or too high gas pressure
Replace correct gas regulator
Gas type not as per nameplate
Use correct gas type
Nozzle or burner holes blocked
Clean up the dirt
Air input not well adjusted
Adjust air input.
Overcooked or
Uncooked rice
Rice pot not evenly placed
Place rice pot evenly.
Warped bottom of rice pot
Replace rice pot.
Heat sensor too dirty
Clean heat sensor.
Water not suitable
Add suitable water.
MODEL
CR 1001G
Type
Gas rice cooker
LPG or NG Optional
Yes (Optional)
Capacity (Liters)
10
Fixed hot load (kW)
7.8
LPG
Gas pressure (Kpa)
2.8
Consumtion (Kg/Cooking)
Max 0.22
NG
Gas pressure (Kpa)
2.8
Consumption (m
3
/Cooking)
Max 0.21
Specifications of this appliance may change without notice to improve the quality of the product. Figures in this manual are
schematic and may not match your product exactly. Values stated on the machine labels or in the documentation accompanying
it are obtained in laboratory in accordance with the relevant standards. Depending on operational and environmental conditions
of the appliance, values may vary.
Part 6:
Trouble Shooting
Part 7:
Specification