English 17
Preparations of installation:
-
If you have a waste pipe outside, t he cooker hood can be connected using extraction duct (enamel,
aluminum, flexible pipe or a fire-resistant mat erial with an inner diameter of 150 mm), see the following
picture:
-
Before installation, switch off the unit and unplug the power c ord from the wall socket.
-
Installation of the cooker hood should be right on the top of the stove with a minimum distance of 65
cm and a height of maximum 75 cm from the surface of the stove.
Installation (DUCTING / EX HAUST System):
Attention! Observe the warning in the instruction sheet concerning the operation of the appliance
when air is discharged from the room.
When the range hood and appliance supplied with energy ot her t han electricity are simultaneously in
operation, the negative pressure in the room must be not exceed 4 Pa (4 × 10
-5
Bar)
-
Drill 3 x 8mm holes to accommodate the bracket. Screw and tighten the bracket onto the wall with the
screws & screw plugs provided.