English 20
-
Sliding the chimney to adjust the chimney height. When the height you required is reached, then fix two
pieces of 4x8mm screws onto the hole fixing with plate I as showed in below pictures :
-
Drill 2 x 8mm holes to accommodate the plate II. Screw and t ighten the plate II onto the wall with two
screws provided.
-
Assembly the chimney onto the unit and fix it with two screws.
Installation (Re-circulating System):
-
If you do not have an outlet to the outside, exhaust pipe is not required and the inst allation is similar to
the one show in section “Installation (DUCTING / EXHAUST System)”.
-
Activated carbon filter can be used to trap odors.
In order to install the activated carbon filter, the grease filter should be detached first by press
the lock and pull it downward.
-
Plug the activated carbon filter into the unit and turn it in clockwise direction. Repeat the same on the