16
Heating Element
If the water contains lime (mud), the heating element cannot function
properly (slow heat) because it was covered by a crust of lime (mud).
Therefore, the heating element must be cleaned of each year.
Contact
MODENA
Customer Care for cleaning.
Check the things below before contacting
MODENA
Customer Care in
the moment of operation disturbance:
Problem
Possible Cause
Recommended Action
Heating indicator
light is off.
Failures on the temperature
controller.
Contact
MODENA
Customer
Care for repair.
Power indicator light
is off.
1.
Power source is not
connected or badly
connected
2.
Indicator light is damaged
3.
Overheating sensor is
activated.
Contact
MODENA
Customer
Care for repair.
No water flows out
from hot water outlet.
1.
Water supply is cut off
2.
Water pressure is too low
3.
Water Inlet valve is not
opened.
1.
Wait for the restoration
of water supply.
2.
Use the water heater
again when the water
pressure is increased.
3.
Open the water inlet
valve of.
Water is not warm
enough.
1.
Heating element is not
active.
2.
Temperature controller is
malfunction.
3.
No power supply to the
water heater.
1.
Replace the heating
element and contact
MODENA
Customer
Care for repair.
2.
Contact
MODENA
Customer Care for
repair.
3.
Check the power
supply.
PART 6: TROUBLESHOOTING
Summary of Contents for Disteso Series
Page 21: ...12 20 ...