Before installing this electric storage water heater, check and ensure 
that  the  power  socket  is  reliably  grounded.  Otherwise,  this  water 
heater  cannot  be  installed  and  used  yet.  Do  not  use  the  extension 

cord if the power socket is damaged. Incorrect installation and use of 
this water heater may result in serious injuries and loss of property. 
 

Special Caution 
 

 

This  appliance  (water  heater)  is  not  intended  to  be  used  by 
persons  with  special  needs  for  their  physical,  sensory  or  mental 

capabilities,  or  lack  of  experience  and  knowledge  (including 
children),  unless  they  have  been  given  the  supervision  or 
instructions concerning the use of the appliance by a person who 

responsible  for  their  safety.  Children  should  be  supervised  to 
ensure that they are not playing with this water heater. 

 

The  wall  in  which  this  water  heater  is  installed  should  be  able  to 

bear  the  twice  bigger  load  than  the  weight  of  this  water  heater 
filled  fully  with  water  without  distortion  and  cracks.  Otherwise, 

other strengthening measures should be adopted. 

 

The  power  socket  must  be  earthed  (grounded)  reliably.  The 

installation height of the power socket should not be lower than 1.8 
m. The rated current of the socket should not be lower than 16A.  

 

The  power  socket  and  the  power  plug  should  be  kept  dry  to 

prevent electrical leakage. If the flexible power cord is damaged, a 
special  power  cord  that  is  provided  by  manufacturer  must  be 

selected,  and  replaced  by  professional  maintenance  personnel. 
Contact 

MODENA

 Customer Care for help. 

 

For  the  correct  operation  of  the  appliance,  it  is  necessary  to  pay 

attention that the maximum inlet water pressure is 0.75 MPa, and 
the minimum inlet water pressure is 0.1  MPa 

 

When using the water heater for the first time (or for the first use 
after maintenance), the water heater cannot be switched on until it 

has been filled fully with water. When filling the water, at least one 
of the outlet valves of the water heater must be opened to exhaust 
the air. This valve  can be closed after the  water  heater  has been 

filled fully with water. 

PART 1: IMPORTANT SAFETY INFORMATION 

Summary of Contents for ES 10 CS

Page 1: ...User Manual Book Electric Storage Water Heater Sano Series ES 10 CS ES 15 CS ES 30 CS ...

Page 2: ...ion 5 Plumbing Connection 7 Part 4 How to Use 9 Part 5 Maintenance 10 Part 6 Troubleshooting 11 Part 7 Disposal of Used Product 12 Part 8 Specification 12 Appendix Wiring Diagram 13 This manual book explains everything you need to know about your new product Please contact our Customer Care should you need further assistance through www modena com ...

Page 3: ...ter without distortion and cracks Otherwise other strengthening measures should be adopted The power socket must be earthed grounded reliably The installation height of the power socket should not be lower than 1 8 m The rated current of the socket should not be lower than 16A The power socket and the power plug should be kept dry to prevent electrical leakage If the flexible power cord is damaged...

Page 4: ...cess there may be drops of water dripping from the pressure relief hole of the pressure relief valve and this is a normal case The pressure relief hole shall not be blocked under any circumstances otherwise the water heater may get damaged or even resulting on accidents If there is a large amount of water leak please contact MODENA Customer Care for repair The pressure relief valve needs to be che...

Page 5: ...n necessary to install a special support In case of the hollow bricks wall ensure to fill the wall with concrete cement completely and use anchor fastener bolt expansion bolt in case of the hebel wall ES 10 CS ES 15 CS ES 30 CS A 324 mm 368 mm 440 mm B 324 mm 368 mm 440 mm C 315 mm 340 mm 388 mm D 66 mm 66 mm 66 mm PART 2 PRODUCT INTRODUCTION PART 3 INSTALLATION Knob Cold Water Inlet Hot Water Out...

Page 6: ...on it Install the power socket in the wall The requirements for the power socket are as follows 250V 10A single phase and three electrodes It is recommended to place the power socket on the top right of the water heater The height of the socket to the ground shall not be less than 1 8 m If the bathroom is too small the water heater can be installed at another place outside the bathroom However in ...

Page 7: ...the threads to ensure the connections are leak proof Power Cord Rubber Seal Gasket Cold Water Inlet Pressure Relief Valve Pressure Relief Hole Hot Water Outlet Joint Screw for the Cold Water Inlet Hot Water Rubber Seal Gasket Adjustable Handle For Mixing Valve Hot Water Power Cord Rubber Seal Gasket Rubber Seal Gasket Hot Water Outlet Adjustable Handle For Mixing Valve Joint Screw for the Cold Wat...

Page 8: ...ol Power Cord Pressure Relief Valve Water Inlet Valve Triple Joint Joint Mixing Valve Shower Head Water Supply Pipe Pipe Water Supply Valve Hot Water Outlet Cold Water Inlet Power Cord Pressure Relief Valve Water Inlet Valve Shower Head Water Supply Valve Water Supply Pipe Pipe Mixing Valve Triple Joint Joint Hot Water Outlet Cold Water Inlet ...

Page 9: ...rature When the water temperature inside the heating tank has reached the set temperature the water heater will switch off automatically If the water temperature falls below the set point the water heater will turn on automatically to restore the default temperature Rotate the knob according to the knob marker to increase or decrease the temperature In a power on state the water heater is heating ...

Page 10: ... not and if necessary replace it with a new one in case of full decomposition Tank cleaning frequency depends on the hardness of the water in each location where this water heater is applied Cleaning must be performed by MODENA or special maintenance services Contact MODENA Customer Care if necessary The water heater is equipped with a thermal switch which cuts off the power supply of the heating ...

Page 11: ... 1 Wait for the water supply to be restored 2 Use the water heater again when the water pressure is increased 3 Open the water inlet valve of running water supply Water Temperature is over high Failure of the temperature control system Contact MODENA Customer Care for repair Water leak Problem on the seal of each pipe joints connection Seal up the joints Manual Reset Button WARNING Non professiona...

Page 12: ...l service Model ES 10 CS ES 15 CS ES 30 CS Product Type Electric Storage Water Heater Electric Storage Water Heater Electric Storage Water Heater Capacity 10 L 15 L 30 L Power 200 W 350 W 350 W Voltage 220 240 V 50 Hz 220 240 V 50 Hz 220 240 V 50Hz Working Pressure 0 1 0 75 MPa 0 1 0 75 MPa 0 1 0 75 MPa Temperature Range 30 65 C 30 75 C 30 75 C Heating Tank Titanium Porcelain Enamel Titanium Porce...

Page 13: ...tly Values stated on the machine labels or in the documentation accompanying it are obtained in laboratory in accordance with the relevant standards Depending on operational and environmental conditions of the appliance values may vary APPENDIX WIRING DIAGRAM Thermostat Thermal Switch Brown Blue Yellow Green Power Indicator Lamp Heating Element Heating Indicator Lamp L N E ...

Page 14: ...12 20 ...