background image

 

5

 

 

 
 
 
 
 
 
 
                      

 

 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

 

 
 

Installation Instruction 

 

 

This  water  heater  should  be  installed  on  a  solid  wall.  If  the 

strength of the wall cannot bear the load equal to twice bigger of 
the total weight of the water heater filled fully with water, it is then 
necessary to install a special support. In case of the hollow bricks 

wall, ensure to fill the wall with concrete cement completely, and 
use anchor fastener bolt (expansion bolt) in case of the hebel wall. 

 

ES 10 CS 

ES 15 CS 

ES 30 CS 

324 mm 

368 mm 

440 mm 

324 mm 

368 mm 

440 mm 

315 mm 

340 mm 

388 mm 

66 mm 

66 mm 

66 mm 

PART 2: PRODUCT INTRODUCTION 

PART 3: INSTALLATION 

Knob 

Cold Water 

Inlet 

Hot Water 

Outlet 

Indicator Light 

 D 

 A 

Summary of Contents for ES 10 CS

Page 1: ...User Manual Book Electric Storage Water Heater Sano Series ES 10 CS ES 15 CS ES 30 CS ...

Page 2: ...ion 5 Plumbing Connection 7 Part 4 How to Use 9 Part 5 Maintenance 10 Part 6 Troubleshooting 11 Part 7 Disposal of Used Product 12 Part 8 Specification 12 Appendix Wiring Diagram 13 This manual book explains everything you need to know about your new product Please contact our Customer Care should you need further assistance through www modena com ...

Page 3: ...ter without distortion and cracks Otherwise other strengthening measures should be adopted The power socket must be earthed grounded reliably The installation height of the power socket should not be lower than 1 8 m The rated current of the socket should not be lower than 16A The power socket and the power plug should be kept dry to prevent electrical leakage If the flexible power cord is damaged...

Page 4: ...cess there may be drops of water dripping from the pressure relief hole of the pressure relief valve and this is a normal case The pressure relief hole shall not be blocked under any circumstances otherwise the water heater may get damaged or even resulting on accidents If there is a large amount of water leak please contact MODENA Customer Care for repair The pressure relief valve needs to be che...

Page 5: ...n necessary to install a special support In case of the hollow bricks wall ensure to fill the wall with concrete cement completely and use anchor fastener bolt expansion bolt in case of the hebel wall ES 10 CS ES 15 CS ES 30 CS A 324 mm 368 mm 440 mm B 324 mm 368 mm 440 mm C 315 mm 340 mm 388 mm D 66 mm 66 mm 66 mm PART 2 PRODUCT INTRODUCTION PART 3 INSTALLATION Knob Cold Water Inlet Hot Water Out...

Page 6: ...on it Install the power socket in the wall The requirements for the power socket are as follows 250V 10A single phase and three electrodes It is recommended to place the power socket on the top right of the water heater The height of the socket to the ground shall not be less than 1 8 m If the bathroom is too small the water heater can be installed at another place outside the bathroom However in ...

Page 7: ...the threads to ensure the connections are leak proof Power Cord Rubber Seal Gasket Cold Water Inlet Pressure Relief Valve Pressure Relief Hole Hot Water Outlet Joint Screw for the Cold Water Inlet Hot Water Rubber Seal Gasket Adjustable Handle For Mixing Valve Hot Water Power Cord Rubber Seal Gasket Rubber Seal Gasket Hot Water Outlet Adjustable Handle For Mixing Valve Joint Screw for the Cold Wat...

Page 8: ...ol Power Cord Pressure Relief Valve Water Inlet Valve Triple Joint Joint Mixing Valve Shower Head Water Supply Pipe Pipe Water Supply Valve Hot Water Outlet Cold Water Inlet Power Cord Pressure Relief Valve Water Inlet Valve Shower Head Water Supply Valve Water Supply Pipe Pipe Mixing Valve Triple Joint Joint Hot Water Outlet Cold Water Inlet ...

Page 9: ...rature When the water temperature inside the heating tank has reached the set temperature the water heater will switch off automatically If the water temperature falls below the set point the water heater will turn on automatically to restore the default temperature Rotate the knob according to the knob marker to increase or decrease the temperature In a power on state the water heater is heating ...

Page 10: ... not and if necessary replace it with a new one in case of full decomposition Tank cleaning frequency depends on the hardness of the water in each location where this water heater is applied Cleaning must be performed by MODENA or special maintenance services Contact MODENA Customer Care if necessary The water heater is equipped with a thermal switch which cuts off the power supply of the heating ...

Page 11: ... 1 Wait for the water supply to be restored 2 Use the water heater again when the water pressure is increased 3 Open the water inlet valve of running water supply Water Temperature is over high Failure of the temperature control system Contact MODENA Customer Care for repair Water leak Problem on the seal of each pipe joints connection Seal up the joints Manual Reset Button WARNING Non professiona...

Page 12: ...l service Model ES 10 CS ES 15 CS ES 30 CS Product Type Electric Storage Water Heater Electric Storage Water Heater Electric Storage Water Heater Capacity 10 L 15 L 30 L Power 200 W 350 W 350 W Voltage 220 240 V 50 Hz 220 240 V 50 Hz 220 240 V 50Hz Working Pressure 0 1 0 75 MPa 0 1 0 75 MPa 0 1 0 75 MPa Temperature Range 30 65 C 30 75 C 30 75 C Heating Tank Titanium Porcelain Enamel Titanium Porce...

Page 13: ...tly Values stated on the machine labels or in the documentation accompanying it are obtained in laboratory in accordance with the relevant standards Depending on operational and environmental conditions of the appliance values may vary APPENDIX WIRING DIAGRAM Thermostat Thermal Switch Brown Blue Yellow Green Power Indicator Lamp Heating Element Heating Indicator Lamp L N E ...

Page 14: ...12 20 ...