English 4
exposed to the vapor. The water may be out-flowed from the pressure relief
valve, so the outlet pipe must be opened wide towards the air. In order to
drain away the water inside the tank (inner container), open up the pressure
relief valve. Twist off the thread screw of the pressure relief valve, and lift the
drain handle upwards (see picture 1). The drainage pipe that connected to
the pressure relief hole must be kept sloping downwards and placed in a
frost-free environment. The water may drip from the discharge pipe of the
pressure relief valve; therefore, this pipe must be left open to the air
(atmosphere).
•
During the heating process, there may be drops of water dripping from the
pressure relief hole of the pressure relief valve, and this is a normal case. The
pressure relief hole shall not be blocked under any circumstances; otherwise,
the water heater may get damaged or even resulting on accidents. If there is
a large amount of water leak, please contact
MODENA
Customer Care for
repair.
•
The pressure relief valve needs to be checked and cleaned regularly, to make
sure it will not be blocked.
•
Since the water temperature inside the water heater can reach up to 75 °C,
the hot water must not be exposed to human bodies when it is initially used.
Adjust the water temperature suitably to the endurance of human skin to
avoid scalding.
•
If any parts and components of this water heater are damaged please
contact
MODENA
Customer Care for repair.