  English   4 

 

exposed to the vapor. The water may be out-flowed from the pressure relief 
valve,  so  the  outlet  pipe  must  be  opened  wide  towards  the  air.  In  order  to 
drain away the water inside the tank (inner container), open up the pressure 
relief valve. Twist off the thread screw of the pressure relief valve, and lift the 
drain  handle  upwards  (see  picture  1).  The  drainage  pipe  that  connected  to 
the  pressure  relief  hole  must  be  kept  sloping  downwards  and  placed  in  a 
frost-free  environment.  The  water  may  drip  from  the  discharge  pipe  of  the 
pressure  relief  valve;  therefore,  this  pipe  must  be  left  open  to  the  air 
(atmosphere). 

 

During the heating process, there may be drops of water  dripping from the 
pressure relief hole of the pressure relief valve, and this is a normal case. The 
pressure relief hole shall not be blocked under any circumstances; otherwise, 
the water heater may get damaged or even resulting on accidents. If there is 
a  large  amount  of  water  leak,  please  contact 

MODENA

  Customer  Care  for 

repair. 

 

The pressure relief valve needs to be checked and cleaned regularly, to make 
sure it will not be blocked. 

 

Since the water temperature inside the water heater can reach up to 75 °C, 
the hot water must not be exposed to human bodies when it is initially used. 
Adjust  the  water  temperature  suitably  to  the  endurance  of  human  skin  to 
avoid scalding. 

 

If  any  parts  and  components  of  this  water  heater  are  damaged  please 
contact 

MODENA

 Customer Care for repair. 

 

 

 

Summary of Contents for ES 10IS

Page 1: ...User Manual Book Electric Storage Water Heater Quadra Series ES 10IS ES 15IS ...

Page 2: ...truction 5 Plumbing Connection 6 Part 4 How to Use 8 Part 5 Maintenance 9 Part 6 Troubleshooting 10 Part 7 Disposal of Used Product 11 Part 8 Specification 12 Appendix Wiring Diagram 12 This manual book explains everything you need to know about your new product Please contact our Customer Care should you need further assistance through www modena com ...

Page 3: ...es should be adopted The power socket must be earthed grounded reliably The installation height of the power socket should not be lower than 1 8 m The rated current of the socket should not be lower than 16A The power socket and the power plug should be kept dry to prevent electrical leakage If the flexible power cord is damaged a special power cord that is provided by manufacturer must be selecte...

Page 4: ...he heating process there may be drops of water dripping from the pressure relief hole of the pressure relief valve and this is a normal case The pressure relief hole shall not be blocked under any circumstances otherwise the water heater may get damaged or even resulting on accidents If there is a large amount of water leak please contact MODENA Customer Care for repair The pressure relief valve n...

Page 5: ...llow bricks wall ensure to fill the wall with concrete cement completely and use anchor fastener bolt expansion bolt in case of the hebel wall After selecting a proper location determine the position of two holes that are used for the installation of the expansion bolts with hook Make two holes on the wall by using a chopping bit with the depth matching to the size ES 10IS ES 15IS A 324 mm 368 mm ...

Page 6: ...cket on the top right of the water heater The height of the socket to the ground shall not be less than 1 8 m If the bathroom is too small the water heater can be installed at another place outside the bathroom However to reduce the heat loss caused by long pipeline the installation position should be as near as possible to the bathroom Plumbing Connection The dimension of inlet and outlet water p...

Page 7: ...the pipelines the provided rubber seal must be installed by the end of the threads to ensure the connections are leak proof If the user wants to make a multi ways supply system refer to the method shown in figure below for connection of the plumbing ...

Page 8: ...emperature When the water temperature inside the heating tank has reached the set temperature the water heater will switch off automatically If the water temperature falls below the set point the water heater will turn on automatically to restore the default temperature Rotate the knob according to the knob marker to increase or decrease the temperature In a power on state the water heater is heat...

Page 9: ...decomposition Tank cleaning frequency depends on the hardness of the water in each location where this water heater is applied Cleaning must be performed by MODENA or special maintenance services Contact MODENA Customer Care if necessary The water heater is equipped with a thermal switch which cuts off the power supply of the heating element upon overheating water or the absence of water in the wa...

Page 10: ... again when the water pressure is increased 3 Open the water inlet valve of running water supply Water Temperature is over high Failure of the temperature control system Contact MODENA Customer Care for repair Water leak Problem on the seal of each pipe joints connection Seal up the joints Manual Reset Button WARNING Non professionals are not allowed to disassemble the thermal switch to do reset P...

Page 11: ...0 W 350 W Voltage 220 240 V 50 Hz 220 240 V 50 Hz 220 240 V 50Hz Working Pressure 0 1 0 75 MPa 0 1 0 75 MPa 0 1 0 75 MPa Temperature Range 30 65 C 30 75 C 30 75 C Heating Tank Titanium Porcelain Enamel Titanium Porcelain Enamel Titanium Porcelain Enamel Heating Indicator Yes Yes Yes Overheat Protection Yes Yes Yes ELCB Yes Yes Yes Magnesium Anode Yes Yes Yes Waterproof Grade IPX4 IPX4 IPX4 Type of...

Page 12: ...English 12 APPENDIX WIRING DIAGRAM Thermal Switch Thermostat Brown Blue Yellow Green Power Indicator Lamp Heating Indicator Lamp Heating Element ...

Page 13: ...03 21 ...

Reviews: