5
C.
Electrical Work
THIS PRODUCT MUST BE GROUNDED
1. A standard electrical outlet must be close to the fire. If the electric outlet is
required to be concealed, it can be located above or on the right hand side of the
fire and behind the face.
2.
DO NOT INSTALL THE FIRE WHERE THE HEATER IS
DIRECTLY ABOVE THE
PLUG SOCKET
. The heat outlet is located in the center at the base of the fire.
3. If the power supply cable becomes damaged in any manner it
MUST
be replaced.
4.
DO NOT
connect the appliance to an extension cord or cable. This can create an
unsafe condition.
5. The fire must not be modified from the manufacturer’s specification in any way and
the appliance must only be used for the purpose recommended by the
manufacturer.
6. If the fire shows any signs of damage it is important that it is examined by a
qualified person.
7. Please observe these instructions as failure to do so may result in electric shock or
other injury.
8. Always ensure that all electrical work complies with the relevant Building Codes.
All electrical work should be carried out by a qualified electrician.
9. If in any doubt contact your supplier or a qualified electrician.