7
Recessed Installation:
1. Prepare frame opening according
to chart.
2. Attach L-metal brackets to the fire
unit with the provided small washer
head screws.
3. Secure fire unit to the finished
framed opening with the provided
large washer head screws. Make cer-
tain that at least 4 of the screws are
driven in to a solid backing. Fireplace
will stand proud of the finished wall
opening by 2.95 cm, this area must
not be blocked by any additional trim,
tile, etc. as this will block proper air
flow.
4. Hang the glass face on the fire
unit. Make certain that the hooks from
the on the backside of the glass face
are secured on all 4 studs on the fire
unit.
A40CLX
25” W x 19 3/4” H x 4” D
A60CLX
45” W x 19 3/4” H x 4” D
A100CLX 85” W x 19 3/4” H x 4” D
Summary of Contents for AMBIANCE LINEAR 100