P a g e  | 11 

3.3.2

 

Electrical Power Connections 

Small wall plug-in convertor power sources must 
NOT be used to power the fireplace because of this 
fireplace’s higher power requirements.  Even under 
the best of conditions, it is only possible to power the 
system using a dedicated line back to the breaker 
box; do not connect to other equipment or outlets 
located in the room. 

 

The information below describes how the main 
electrical connections must be setup when using the 
“Flame Only” function or when using both the flame 
and heater functions (Figure 10). 

 

3.3.2.1

 

Connect: Flame Only (No Heater) 

A single 120 Volt, 20 Amp power connection, which 
is a dedicated line back to the breaker box (one run 
of “Solid Romex 12/2 CU NM-B W/G” cable 
recommended), is used to connect the main power 
directly to the fireplace when only the simulated 
flame is needed. 

3.3.2.2

 

Connect: Flame & Heater 

Two 120 Volt 20 Amp, dedicated lines back to the 
breaker box (2 runs of “Solid Romex 12/2 CU NM-B 

W/G” or 1 run of “Solid Romex 12/4 CU NM-B W/G” 
cable recommended). 

3.3.3

 

Water Supply 

3.3.3.1

 

Water purity 

A Reverse Osmosis (R.O.) system is required for 
commercial installations.  Boiler life is extended 
when the water supply contains low amounts of 
dissolved solids.  For residential applications, an RO 
system is not required, but recommended for 
extended boiler life. 

3.3.3.2

 

Water line connection 

When connecting to a fresh water supply, use a ¼” 
polyurethane water line with a John Guest fitting 
connected to an in-line ball valve. 

3.3.3.3

 

Manual fill option 

A water line is not mandatory for operation.  Manual 
fill is available and comes standard with each 
fireplace.  When the water supply container level 
gets low, a warning is shown on the display to 
remind the user to refill the container. 

Although not required, using a Reverse Osmosis 
(R.O.) or distilled water source to refill the water 
supply is highly recommended for extended life. 

3.3.4

 

Venting 

3.3.4.1

 

Optional venting requirements 

Please refer to Figure 11 for the location of the vent 
and the vent slider control.  Note that a 6” vent duct 
is recommended in installations in a room that has 
an area of less than 500 square feet. 

Note: 

When using the heater, the external vent 

should NOT be used.  This will prevent heat from 
escaping to the outside. 

To prepare the vent connection, remove the 
protective plate from the top of the fireplace and 
install the Vent Duct Flange in its place to use for the 
duct connection. 

A length of venting duct and the Vent Duct Flange, to 
which is attached, are included with the fireplace 

Accessory Kit

 (sold separately).  The length of this 

duct is 20 feet and is the MAXIMUM length of duct 
that can be used.  Using a longer length duct run will 
result in improper ventilation of steam during 
operation.  

WARNING – WIRE DIRECTLY TO A 

DEDICATED 20A BREAKER 

 

Figure 10 

Summary of Contents for FusionFire 60

Page 1: ...Rev 7 Copyright 2017 2018 all rights reserved U S and Foreign Patents Pending FusionFireTM Steam Fireplace INSTALLATION USER S MANUAL ...

Page 2: ...3 Preparation 8 3 3 1 Framing for Wall Build In 10 3 3 1 1 Framing Details 10 3 3 2 Electrical Power Connections 11 3 3 2 1 Connect Flame Only No Heater 11 3 3 2 2 Connect Flame Heater 11 3 3 3 Water Supply 11 3 3 3 1 Water purity 11 3 3 3 2 Water line connection 11 3 3 3 3 Manual fill option 11 3 3 4 Venting 11 3 3 4 1 Optional venting requirements 11 3 3 4 2 Steam safety 12 3 4 Installation 12 3...

Page 3: ...gement office NOTE The advisories on this page will be updated with the appropriate information upon completion of U L compliance testing This product is guaranteed for 2 years from the date of installation as set out in the terms and conditions of sale between Modern Flames and your local dealer This guarantee will be invalid to the extent permitted by law if the appliance has not been installed ...

Page 4: ...ine included for plumbed installations allows automatic filling If no water source available manual water filling allows for 12 hours of continuous use Integrated water filter system ensures clean operation and full rated product life FauxFire technology is a patented simulated flame system that utilizes steam and lighting techniques to create a realistic flame effect 1 2 2 Basic and Optional Feat...

Page 5: ... shock or injury to persons 9 Do not attempt to make electrical or mechanical adjustments or repairs without the services of qualified personnel 10 Do not make any electrical connections even temporary under carpeting along baseboards etc All electrical connections to this appliance must be done within walls and in accordance with local electrical codes 11 The appliance is hardwired and has no mai...

Page 6: ...ed since the fireplace was first powered up Typically this should not be more than a few minutes C When the startup sequence is complete the Ready indicator will appear and the unit is fully operational D When the water reservoir it low the Add Water indicator will come on to warn that more water should be added for continued operation E When it is necessary to replace the water filter the Change ...

Page 7: ...rfaces until ready to operate the fireplace see Figure 4 This will protect from dust contamination and scratches during installation 3 2 Fitting the Fireplace 3 2 1 Location of the Fireplace The fireplace may be installed at any indoor location However when choosing a location please keep in mind the following guidelines Install out of direct sunlight for maximum performance Select a suitable loca...

Page 8: ...nter of the fire display area is properly located within the room as planned in advance 3 3 Preparation There is one power connection or two power connections if heater is used a water supply connection connection optional and a vent pipe connection optional that must be put in place by the installer Figure 7 The user controls are self contained and are accessed either by using the Settings Pad as...

Page 9: ...P a g e 9 Figure 7 ...

Page 10: ...ming Details Please reference the Display Window Centerline drawing Figure 6 above and the Installed Fireplace Illustrations Figures 8 9 to be sure the fireplace is properly centered in the room NOTE The fireplace becomes heavy when its water reservoir is full To prevent undue stress on the framing use a platform constructed from plywood to support the entire assembly before finishing For best per...

Page 11: ...ed for extended boiler life 3 3 3 2 Water line connection When connecting to a fresh water supply use a polyurethane water line with a John Guest fitting connected to an in line ball valve 3 3 3 3 Manual fill option A water line is not mandatory for operation Manual fill is available and comes standard with each fireplace When the water supply container level gets low a warning is shown on the dis...

Page 12: ... bottom support Then locate the Water Leak Sensor which is attached to the rear of the fireplace in a small plastic bag After removing the sensor from the bag slide it into the small slot located on the front right corner of the mat Be sure the two connecting wires are facing up to allow connection to the fireplace and face the printed circuit pattern down If the sensor gets wet it will trigger a ...

Page 13: ...nit It is recommended that this tubing be joined to the water feed line by using a John Guest quick connect union supplied as shown in Figure 14 It is also recommended that a compression fitting with a shut off valve be fitted at the water source a ball valve of the type shown in the Figure 15 not supplied Note There is another water shut off valve that is accessible through the front of the firep...

Page 14: ...ex 12 2 CU NM B W G or Solid Romex 12 4 CU NM B W G cable AC Circuit Breakers The AC breaker panel circuit protection is required to be 20A single pole circuit breaker 15A not allowed The auxiliary heater must be on a separate dedicated breaker Terminating AC Connections Once the wiring has been run between the breaker panel and the fireplace terminate see Figure 17 above the appropriate conductor...

Page 15: ...he probes together and verify a reference reading for 0 Ohms or a very low value as shown in Figure 18 2 Connect the multimeter between the copper grounding bar and the green wire connection on the fireplace s AC input screw terminal as shown in Figures 19a and 19b Verify that the reading is 0 Ohms within 0 1 Ohms of the reference value previously noted Figure 18 Figure 19a Ground Bar Figure 19b A...

Page 16: ...viously noted 4 Likewise connect the multimeter alternatively between the copper grounding bar and the side metal rear metal light bar and boiler metal parts of the fireplace Verify that the readings are within 0 1 Ohms of the reference value for each test If any of the reference readings are 0 2 Ohms or greater contact a factory representative before completing the installation Figure 20b Front P...

Page 17: ...l stop 3 4 4 3 Construction Barrier After the fireplace is installed the drywall is finished construction is complete and there is no debris on the site remove the cardboard construction barrier from the front see Figure 21 Then carefully remove the protective film from the media bed by removing the tape holding it in place 3 4 5 Final start up procedure Make sure all connections and the fireplace...

Page 18: ... to start the fireplace It will begin in Warm Up mode the text Initializing Please Standby shown in Figure 25 is displayed A countdown timer displays time remaining while it warms up As soon as the fireplace is ready to operate after about 3 minutes you will see a Ready display see Figure 26 along with the total run time that has been accumulated for the fireplace After a short delay the simulated...

Page 19: ...ive during operation 3 4 5 4 Draining the Reservoir Boiler Should it become necessary to drain the boiler and reservoir a T valve is positioned in the water line between the Steam Subsystem pump and the manifold inlet A recoil type drain hose of length 2m 5m is connected to the T valve and stored for use beneath the media bed To drain the water tank for winterizing the T valve see Figure 28 is use...

Page 20: ...a life span of up to 20 years Q Can the fireplace be installed outside A No Please review the entire safety sections before installing this fireplace Q Does the fireplace need to be on a dedicated 20 Amp circuit A Yes and two dedicated 20 Amp circuits must be wired when the heater is used Q What thickness of drywall should be used for the recessed installation A 1 2 or 5 8 Q How often does the bat...

Page 21: ...r and its control board Boiler control board is defective Replace the control board with one of the same model and part Nothing comes on front panel screen etc There is a problem with the keypad and or its mounting that is preventing the buttons from functioning Reposition the fireplace in the installation so that no part of the fireplace is interfering with the keypad controls Check that there is...

Page 22: ...e battery in remote control with a 2032 coin cell Not aiming control correctly Aim remote control to the upper right of the viewing area where sensor is located Remote control defective Replace remote control Remote Sensor is defective Replace remote sensor inside fireplace Aux heater does not function and or Fault code 16 AUX HEATER FAILURE is shown on the display Heater wiring is loose at firepl...

Reviews: