P a g e | 12
Make sure the steam vent slider lever (shown in
Figure 11) on the front panel is in the closed position.
This will cause the internal fan to force the steam out
via the vent rather than the front of the fireplace.
3.3.4.2
Steam safety
Because pure steam contains no chemicals or
breathing hazards, it is safe to operate without an
external vent. The only concerns are in situations
where there is high ambient humidity or small room
installations where humidity may build up to
uncomfortable levels.
3.4
Installation
3.4.1
Mat and Water Leak Sensor
Before installing the fireplace in the wall opening,
place the mat (Figure 12) on the heavy plywood
bottom support. Then, locate the Water Leak Sensor
which is attached to the rear of the fireplace in a
small plastic bag.
After removing the sensor from the bag, slide it into
the small slot located on the front right corner of the
mat. Be sure the two connecting wires are facing up
to allow connection to the fireplace and face the
printed circuit pattern down.
If the sensor gets wet, it will trigger a Fault Code to
indicate water is accumulating in the mat.
3.4.2
Fitting the Fireplace
Install the fire unit in the framed opening while noting
the width dimension illustrated in Figure 13. This
shows the entire width, including the Fastening Tabs.
3.4.2.1
Fastening Tabs
Use drywall screws with a minimum length of 1¼” to
secure the unit to the framed opening using the L-
shaped metal fastening tabs attached to the sides of
the fireplace.
Figure 12
Figure 11