circuit connection to the heater, turn the heater on,
and verify that the current draw on that circuit is 16
Amps or less.
3.4.5.3
Fire Bed Media Installation
The Fireplace package includes a 10 Lb. bag of
decorative glass media. Optional media can be
selected by the user and separately placed by the
installer.
The media must be evenly distributed over the
bottom metal panel that covers the water reservoir.
This it done to maximize the fire ember effect when
the lighting is active during operation.
3.4.5.4
Draining the Reservoir/Boiler
Should it become necessary to drain the boiler and
reservoir, a T-valve is positioned in the water line
between the Steam Subsystem pump and the
manifold inlet. A “recoil” type drain hose of length 2m
+/- .5m is connected to the T valve and stored for
use beneath the media bed.
To drain the water tank for winterizing, the T-valve
(see Figure 28) is used to route water from the pump
out the drain hose. One end of the drain hose is
pulled out of the fireplace and placed into an external
bucket. The pump is activated during system power
ON by pressing and holding both “up/down” Adjust-
Buttons on the keypad simultaneously.