background image

 7 

 

INSTALLATION 

INSTALLATION 

WARNING - RISK OF FIRE!

 

The  power  cord  must  not  be  pinched  or 
against  a  sharp  edge.  Secure  cord  to 
avoid tripping or snagging to reduce the 
risk of fire, electric shock or personal in-
jury.

  

Do not run cord under carpeting. Do not 
cover  cord  with  throw  rugs,  runners  or 
the  like.  Arrange  cord  away  from  traffic 
areas  and  where  it  will  not  be  tripped 
over.

 

WARNING - RISK OF FIRE!

 

To  prevent  a  possible  fire,  do  not  block 
air  intake  or  exhaust  in  any  manner.  Do 
not use on soft surfaces where openings 
may become blocked.

 

WARNING - RISK OF FIRE!

 

Do  not  blow  or  place  insulation  against 
the firebox.

 

Installing fireplace

 

Select  a  suitable  location  that  is  not  suscep-
tible  to  moisture  and  is  a  safe  distance  from 
drapes,  furniture  and  high  traffic  areas.  A 
qualified  electrician  should  add  an  electrical 
outlet  per  local  building  codes.  See  shaded 
area  on  recessed  installation  diagram  for 
proper  outlet  placement. 

Fireplace  must  be 

installed  to  a  plumb  vertical  wall  for  cor-
rect operation of touch controls.

 

Note:  Follow  all  national  and  local  electrical 
codes. This fireplace can be framed in to the 
wall.

 

WARNING: If the information in these in-
structions  is  not  followed  exactly,  a  fire 
or explosion may result causing property 
damage, personal injury or death.

 

To reduce the risk of fire do not store or 
use  gasoline  or  other  flammable  vapors 
in the vicinity of this or any other heater.

 

Electrician should add a 
2200v outlet to the rear 
portion of the right side 
of the framed opening 
(see the shaded panel.) 

Summary of Contents for HF1200CBI

Page 1: ...Home Fire CBI Electric Series HF900CBI HF1200CBI HF1500CBI INSTALLATION SERVICE INSTRUCTIONS FOR USE IN UNITED STATES AND CANDA ...

Page 2: ...ctric heaters have hot and arcing or sparking parts inside Do not use it in areas where gasoline paint or flammable liquids are or are stored This fireplace meets the construction and safety standards of H U D for application in manufactured homes when installed according to these instructions INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference ...

Page 3: ...over 10 To disconnect heater turn controls to the OFF before removing plug from outlet 11 Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock or fire or damage the heater WARNING Improper installation adjust ment alteration service or maintenance can cause injury or property damage Refer to this manual For assistance or additional ...

Page 4: ...door down to open 23 Do not let children play with the appliance unsupervised 24 Heater must not be located immediately below a socket outlet 25 The appliance is not to be used by children or persons with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision and instruction 26 If the supply cord is damaged it must be replaced by...

Page 5: ... Viewing Area Face Dimensions Firebox Dimensions HF900CBI 762mm W x 445mm H 914mm W x 743mm H 821mm W x 681mm H x 291mm D HF1200CBI 914mm W x 445mm H 1067mm W x 743mm H 974mm W x 681mm H x 291mm D HF1500CBI 1372mm W x 445mm H 1524mm W x 743mm H 1431mm W x 681mm H x 291mm D Width varies see chart below 743mm all models ...

Page 6: ...n AC 220V 50Hz 4W CCW 15 18 r min Shipping Size 1562x314x787mm 1105x314x787mm 953x314x787mm UNPACKING AND TESTING Carefully remove unit from box Prior to per manently installing unit test to make sure unit operates properly To do this plug unit s power supply cord into a conveniently located 220 volt grounded outlet CAUTION The unit s power supply cord must be connected to a properly grounded and ...

Page 7: ...n that is not suscep tible to moisture and is a safe distance from drapes furniture and high traffic areas A qualified electrician should add an electrical outlet per local building codes See shaded area on recessed installation diagram for proper outlet placement Fireplace must be installed to a plumb vertical wall for cor rect operation of touch controls Note Follow all national and local electr...

Page 8: ...a solid backing Fireplace will stand proud of the finished wall opening by 10mm This is a semi permanent installation Remove screws to relocate 4 Connect the fire feature to the inside of the fire unit 5 Hang the glass face on the fire unit Make certain that the hooks from the on the backside of the glass face are secured in all 4 slots on the fire unit 6 Install the grid in to the glass face Powe...

Page 9: ...n to turn the machine on This will be indicated by 1 orange LED light The Heat button can be pressed multiple times and will turn on low high and off in that order The Backlight button turns on high medium low and off in that or der Power Heat Backlight When the switch turns on this orange pilot lamp is always on It shows the fire is ener gized The status light above shows that the power is on and...

Page 10: ...ROL IR RECEIVER MF12VT1 TRANSFORMER MFHF12015 HEATER FAN 220 V 1 5kW MFPHF HF HEATER 220 V 1 5kW MFSM120 SPINDLE MOTOR 220 V 50 60 HZ MFPHF36 LED LED LIGHT STRING HF900CBI MFPHF42 LED LED LIGHT STRING HF1200CBI MFPHF60 LED LED LIGHT STRING HF1500CBI MF PS1 POWER SWITCH MFR1 REMOTE CONTROL HFGLS36 GLASS FACE HF900CBI HFGLS42 GLASS FACE HF1200CBI HFGLS60 GLASS FACE HF1500CBI ...

Page 11: ...n will be able to adjust the touch screen sensi tivity Q Can the fireplace be installed outside A No Please review the entire safety chapter before installing this fireplace Q Does the fireplace need to be on a dedicated 15 amp circuit A Yes Q What thickness of sheetrock should be used for the recessed installation A 12mm or 16mm Q How often do the batteries in the remote need to be replaced A Ann...

Page 12: ...rrectly on pins B Fireplace was installed with the power in on position B Turn main power switch to the off position for 30 seconds Switch the fireplace back into the on position for 20 seconds for complete reboot of touch control C Not operating touch control properly with finger C Press flat part of finger firmly on the touch screen and apply moderate pressure D Loose connection on motherboard D...

Page 13: ...ve B Replace motor CLEANING AND MAINTENANCE INSTRUCTIONS There is very little maintenance involved with your electric fireplace Please follow the few points be low On a semi annual basis unplug the machine from it s power source and wait for the heating ele ment to cool dust the fire unit and glass face with a dry cloth Be careful not to brush any wires that may be exposed as you do this To clean ...

Page 14: ...14 MAINTENANCE NOTES ...

Page 15: ...15 MAINTENANCE NOTES ...

Page 16: ...16 2012 www modernflames com Please dispose of properly ...