background image

   

 

Landscape Fullview Series 

LFV100015-SH • LFV150015-SH• LFV200015-SH 

LFV250015-SH • LFV300015-SH 

INSTALLATION/SERVICE INSTRUCTIONS 

CE RATED FOR 220-240V 50HZ INSTALLATIONS 

Summary of Contents for LFV100015-SH

Page 1: ...Landscape Fullview Series LFV100015 SH LFV150015 SH LFV200015 SH LFV250015 SH LFV300015 SH INSTALLATION SERVICE INSTRUCTIONS CE RATED FOR 220 240V 50HZ INSTALLATIONS ...

Page 2: ...ginning installation Failure to follow them could cause a heater malfunction resulting in serious injury and or property damage WARNING All electric heaters have hot and arcing or sparking parts inside Do not use it in areas where gasoline paint or flammable liquids are or are stored INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference ...

Page 3: ...t least 3 feet 0 9m from the front of the heater and keep them away from the sides and rear 3 Extreme caution is necessary when any heater is used by or near children or disabled people and whenever the heater is left operating and unattended 4 Do not operate any heater after it malfunctions has been dropped or damaged in any manner Disconnect power at service panel and have heater inspected by an...

Page 4: ...1mm x 356mm 1981mm x 661mm x 356mm 2489mm x 661mm x 356mm 2997mm x 661mm x 356mm 3505mm x 661mm x 356mm USER INSTRUCTIONS PRODUCT GUIDE Width varies see chart below 292mm all models 572mm all models Model Viewing Area Firebox Dimensions Framing Dimensions LFV100015 SH 1016mm W x 381mm H 1391mm W x 572mm H x 292mm D 1416mm W x 585mm H x 305mm D LFV150015 SH 1524mm W x 381mm H 1899mm W x 572mm H x 2...

Page 5: ... location that is not suscep tible to moisture and is a safe distance from drapes furniture and high traffic areas A qualified electrician should add a flexible 10 amp 220 240 volt circuit per local building codes Note Follow all national and local electrical codes WARNING If the information in these in structions is not followed exactly a fire or explosion may result causing property damage perso...

Page 6: ... hard wire to the terminal block according to the diagram below Choose any connector type according to local building code Terminal block Model H W D LFV100015 SH 585mm 1416mm 305mm LFV150015 SH 585mm 1924mm 305mm LFV200015 SH 585mm 2432mm 305mm LFV250015 SH 585mm 2940mm 305mm LFV300015 SH 585mm 3448mm 305mm W H D To be performed by a qualified electrician according to local building codes ...

Page 7: ...uring the drywall process Install drywall to the drywall stops on the perimeter of the fire insert For more information on the drywall stops see the Product Guide on page 4 Decorate as desired 6 After installation user may elect to use the L Metal Deco Trim To install use a small amount of construction adhesive and secure to the drywall face ...

Page 8: ...ling a fire feature Canyon Juniper Log set Crystal Glass Coal set Installing remote touch control 2 Follow the instructions included with the fire feature 1 Locate and remove the access door on the rear right side of the fire unit 2 Locate the remote touch control directly inside the access panel Pull the touch control through the access panel and replace the access door Locate the touch control a...

Page 9: ...peration Touch the power button to turn the machine on This will be indicated by 1 orange LED light The Heat button can be pressed multiple times and will turn on low high and off in that order The Backlight button turns on high medium low and off in that order Power Heat Backlight When the switch turns on this orange pilot lamp is always on It shows the fire is energized The status light above sh...

Page 10: ...T HAND MFHF24015 LH HEATER FAN 220 240V 1 5kW LEFT HAND MFPHF240AL HEATER 220 240V 75kW MFSM240 SPINDLE MOTOR 220 240V 50 60 HZ MFPLS40 LED LED LIGHT STRING LS 40 MFPLS60 LED LED LIGHT STRING LS 60 MFPLS80 LED LED LIGHT STRING LS 80 MFPLS100 LED LED LIGHT STRING LS 100 MFPLS120 LED LED LIGHT STRING LS 120 MFR1 REMOTE CONTROL MFLSGF40 INNER GLASS FACE MFLSGF60 INNER GLASS FACE MFLSGF80 INNER GLASS ...

Page 11: ...es Q What thickness of sheetrock should be used for the recessed installation A 12mm or 16mm Q How often do the batteries in the remote need to be replaced A Annually possibly more with heavy use Q Is there a remote receiver in the fireplace that requires batteries A No only the actual remote requires batteries The rest of the fireplace runs entirely off of the main power supply PROBLEM POSSIBLE C...

Page 12: ...the breaker back into the on position for 20 seconds for complete reboot of touch control C Not operating touch control properly with finger C Press flat part of finger firmly on the touch screen and apply moderate pressure D Loose connection on motherboard D Check functions with remote control if functional check connections on motherboard E Motherboard is defective E Replace Motherboard Fireplac...

Page 13: ... desired glass cleaner with paper towels To clean the air inlets outlets wipe with a soft cloth or the nozzle of a vacuum cleaner Dust can easily build up around the heater area under the appliance Take particular care to clean this area on a regular basis to prevent buildup WIRING DIAGRAM PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION A Wiring is loose A Disconnect unit from power source and inspect fo...

Page 14: ...14 MAINTENANCE NOTES ...

Page 15: ...15 NOTES MAINTENANCE ...

Page 16: ...16 2013 2015 www modernflames com Please dispose of properly Ver 4 ...