When  using  any  electrical  devices,  basic 
precautions  should  always  be  followed  to 
reduce  the  risk  of  fire,  electric  shock  and 
injury to persons, including the following: 
 
1.  Read all instructions before using this 

device. 

2.  Always use properly grounded fused and 

WARNING: 

Improper 

installation, 

adjustment, 

alteration, 

service 

or 

maintenance 

can 

cause 

injury 

or 

property  damage.  Refer  to  this  manual. 
For  assistance  or additional  information, 
consult a qualified installer.  

polarized outlets. 

3.  Use this device only as described in this 

manual. Any other use not recommended 
by the manufacturer may cause fire, 
electric shock or injury to persons. 

4.  Always use ground fault protection where 

required by electrical codes. 

5.  Always disconnect power before 

performing any cleaning, maintenance or 
relocation of device. 

6.  To prevent electric shock or fire, always 

use a certified electrician should new 
circuits or outlets be required. 

7.  When transporting or storing device, keep 

in a dry place. 

8. 

Do not let children play with the appliance 

Carefully  remove  unit  from  box.  Prior  to 
permanently  installing  unit,  test  to  make  sure 
unit  operates  properly. 

A  qualified  electrician 

should add a flexible 15 amp 120V circuit per 
local building codes. 

 

WARNING: Do not operate the unit if it is 
damaged  or  has  malfunctioned.  If  you 
suspect  the  unit  is  damaged,  return  the 
unit  to  an  authorized  service  facility  for 
examination,  electrical  or  mechanical 
adjustment or repair.  

USER INSTRUCTIONS 

Important Instructions .................................. 2 
Contractor Instructions ................................. 2 
Unpacking and Testing ................................ 2 
Product Dimensions ..................................... 3 
Box Contents ............................................... 3 

Power Data .................................................. 3 
Locating Fireplace ....................................... 4 
Installation ................................................... 4 
Operation .................................................... .6 
Service Parts .............................................. .6 

IMPORTANT INSTRUCTIONS 

UNPACKING AND TESTING 

Home builder or contractor must provide the following: 
 

 

Framed opening according to chart on page 5. Opening should be waterproof if on an exterior 
wall. 

 

Switched 120V electrical flexible hardwire power supply. Switch may be 120V wall switch, time 
clock or circuit breaker at customer’s option. 

CONTRACTOR INSTRUCTIONS 

Summary of Contents for NOVA 60

Page 1: ... result in serious injury INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference NOVA 60 INDOOR OUTDOOR RECESSED ELECTRIC FIREPLACE SAFETY INFORMATION AND OPERATIONS MANUAL Wall Switch Ready for on off operation no remote control option for this fireplace ...

Page 2: ...or outlets be required 7 When transporting or storing device keep in a dry place 8 Do not let children play with the appliance Carefully remove unit from box Prior to permanently installing unit test to make sure unit operates properly A qualified electrician should add a flexible 15 amp 120V circuit per local building codes WARNING Do not operate the unit if it is damaged or has malfunctioned If ...

Page 3: ... 57 1 4 W x 17 7 8 H x 5 D USER INSTRUCTIONS PRODUCT DIMENSIONS POWER DATA 60 18 7 8 7 1 8 BOX CONTENTS Nova 60 Fireplace Coal Bed Media Installation Hardware Installation Manual Owners Manual Model Voltz HZ Amps Lamps Rotor motor NOVA 60 AC 120V 60Hz 1 5 Amps LED DC 12V CCW 15 18 r min 54 12 7 8 ...

Page 4: ...g fireplace Select a suitable location that is not susceptible to moisture A qualified electrician should add a flexible 15 amp 120 volt circuit per local building codes Note Follow all national and local electrical codes INSTALLATION LOCATING FIREPLACE INSTALLATION Recessed Home builder or contractor must provide the following Framed opening according to chart on page 5 Opening should be waterpro...

Page 5: ... ball catches start to separate Once you have separated the glass face from the fire unit place the decorative glass face in a safe location 3 Connect hard wire to the terminal block according to the diagram below Choose any connector type according to local building code Framing Dimensions Nova 60 57 1 4 W x 17 1 8 H x 5 D INSTALLATION Terminal block To be performed by a qualified electrician acc...

Page 6: ...he fire unit with the holes on the back of the decorative glass face Gently push the glass face onto these posts starting at any corner until you hear the ball catches start to engage Continue around the entire OPERATION This fireplace has no controls or remote for operation It is simply operated by the wall switch time clock or circuit breaker installed by the contractor or home builder REMINDER ...

Page 7: ...7 MAINTENANCE NOTES ...

Page 8: ...8 2016 www modernflames com Please dispose of properly ...