15
https://www.modernflames.com
Wall Mounted Installation
NOTE: A dedicated 20 Amp (or higher), 2-pole (for 10,000 BTU
’s), breaker is
required.
•
Select a location that is not prone to moisture and is located at least 36" (914mm) away from
combustible materials such as curtain drapes, furniture, bedding, paper, etc.
•
Have two people hold the appliance against the wall to determine the final location.
•
Place the unit down on a soft, non-abrasive surface.
•
Remove the wall bracket from the back of the unit by removing the screws (Fig. 4-1). Set screws
aside.
For best results, keep the side skirts installed onto the fireplace.
•
After you have selected a suitable location for wall mounting, locate the studs on the wall. You
must be able to secure to a minimum of 2 studs for proper installation of the bracket.
•
Using the wall bracket as a guide, mark the mounting hole locations.
•
This bracket MUST have the hooks facing upward and be level (Fig. 4-2).
•
Additional support is provided by using the included wall anchors (
B
) between the studs.
•
Additional wall anchors must be installed prior to the wall bracket being mounted.
i.
To install additional wall anchors, pre-drill (optional) all locations with a 1/8" drill bit.
ii.
Install the wall anchors with a Philips tip screwdriver.
•
Install the wall bracket to the studs using #8
– 1-5/8" (
A
) screws and to the wall anchors with a
#8
– 1" screws (
C
).
FAILURE TO DO SO CAN RESULT IN PERSONAL INJURY
AND/OR DAMAGE TO EQUIPMENT.
Due to different materials used on different walls, it is highly recommended for
you to consult with your local builder before you install this electric fireplace.
Fig. 4-1