Hardwiring Installation
A qualified electrician must wire this fireplace to a dedicated 110~120 volt, 20 amp, circuit.
NOTE: A dedicated 20 Amp (or higher), 2-pole (for 10,000 BTU
’s), breaker is
required.
The appliance must be electrically connected and grounded in accordance with local codes. In the
absence of local codes, use the current CSA C22.1 Canadian Electrical Code in Canada or the current
ANSI/NFPA 70 National Electrical Code in the USA.
12
0 Volt Power (5,000 BTU’s)
:
Note:
There are 3 wires from the appliance junction box: white (neutral), black (power L1), and green/bare (ground)
that are connected to 120V power source (circuit breaker panel).
•
Ensure power from the circuit breaker is off.
•
Remove the 2 securing screws from the junction box cover plate, located on the top left-hand, back-
side of the appliance (Fig. 5-1).
•
From the power supply wire, connect the green/bare copper wire to ground (
G
), the white wire to
neutral (
N
), and the black wire to Line1 (
L1
) (Fig. 5-2).
•
Resecure the junction box cover plate using the 2 screws previously removed.
Fig. 5-1
Fig. 5-2