Hardwiring Installation (Continued)
240 Volt Power
(10,000 BTU’s)
:
This fireplace is equipped with the ability to optionally wire with 240 volts
, which will supply 10,000 BTU’s
of heat.
A qualified electrician must wire this fireplace to a dedicated 220~240 volt, 20 amp, circuit.
Note:
There are 4 wires from the appliance junction box: white (neutral), black (power L1), red, (power L2), and
green/bare (ground) that are connected to 220V power source (circuit breaker panel).
•
Ensure that power from the circuit breaker is off.
•
Remove the 2 securing screws from the junction box cover plate, located on the top left-hand, back-
side of the appliance (Fig. 6-1).
•
In the hardware kit, locate the terminal screw (with accompanied clamp plate) (
D
) that match the
existing screws and clamp plates of the terminal block. Screw the terminal screw into the open position
of the terminal block.
•
From the 4-wire, 240 volt power supply wire, connect the green/bare copper wire to ground (
G
), the
white wire to neutral (
N
), the black wire to Line1 (
L1
), and the red wire to Line2 (
L2
) (Fig. 6-2).
•
Re-secure the junction box cover plate using the 2 screws previously removed.