Hard wiring installation
HARD WIRING CONNECTION
If it is necessary to hard wire this appliance, a qualified electrician must remove the cord connection, and wire
the appliance directly to the household wiring.
NOTE: A dedicated 10 Amp (or higher) breaker is required.
This appliance must be electrically connected and grounded in accordance with local codes if hard wired.
TURN OFF POWER FROM CIRCUIT BRACKER FIRST
A.
Remove the cover plate from the right side bottom of the appliance by removing the three screws,
as shown above. (SEE FIG.1)
B.
Remove the wire nuts from the power cord. The power cord may be discarded. (SEE FIG.2)
C.
Take the new cover plate, supplied in the hardware bag and punch out the 7/8" (22.2mm) hole and install
cable connector through into the junction box. Snap the cable connection clamp onto the supply wires.
D.
Using the wire nuts, connect the ground green wires (G), the common white wires (N)
together, then the hot black wires (L), (SEE FIG.3).
E.
Re-install the cover plate using the three screws, as shown in FIG.1.
TURN OFF THE APPLIANCE COMPLETELY AND LET COOL BEFORE SERVICING. ONLY A QUALIFIED SERVICE
PERSON SHOULD SERVICE AND REPAIR THIS ELECTRIC APPLIANCE.
WARNING
Cover plate (
J
)
12
Cable connector
(
I
)
Summary of Contents for SPS-100B-AU