Recessed pre-installation
Due to the many different materials used on different walls, it is highly recommended that you
consult your local builder before you install this appliance on the wall.
A. Select a location that is not prone to moisture and is located at least 36” (94.1cm) away from
combustible materials such as curtain drapes, furniture, bedding, paper, etc.
B. Measure the appliance and create a rough-in frame with electrical (see below “framing”).
C. Remove the front glass (see “front glass removal / installation” section).
D. Hold the appliance up to ensure it will fit into the framing.
Power
FINISHED OPENING DIMENSIONS
Model Number
A
B
C
SPS-50B-AU
48-7/8"
(1242mm)
16-1/4"
(413mm)
4" min.
(102mm min.)
SPS-60B-AU
58-7/8"
(1496mm)
16-1/4"
(413mm)
4" min.
(102mm min.)
SPS-74B-AU
72-7/8"
(1851mm)
16-1/4"
(413mm)
4" min.
(102mm min.)
SPS-100B-AU
98-7/8"
(2512mm)
16-1/4"
(413mm)
4" min.
(102mm min.)
(Non-Load Bearing)