FR-W1811
Aviator Instructions
12
2. Hanging the Fan
1. Disconnect power at the breaker to the fan location.
A licensed electrician must install the fan.
2. Remove 1 of 2 screws from the bottom of mounting bracket and
save for use in the Finishing the Installation section. Loosen the
other screw (Fig. 2).
3. Pass the 120-volt supply wires through the center hole in the
ceiling mounting bracket as shown in (Fig. 2).
4. Secure the mounting bracket to the ceiling outlet box with the
screws and washers provided with your outlet box (Fig. 2).
5. Remove the clevis pin and cotter pin and loosen the two collar
screws from the motor collar (Fig. 2).
6. Feed motor wires through coupling cover, canopy ring, and canopy.
7. Feed motor wire through downrod assembly.
8. Thread the downrod assembly onto motor collar. Align the holes
of downrod and collar and insert the cotter pin and clevis pin.
Tighten the two collar screws (Fig. 2).
9. Carefully lift the fan motor assembly up to the mounting
bracket and seat the hanger ball in the mounting bracket
socket. Make sure the tab on the mounting bracket socket is
properly seated in the groove in the hanger ball (Fig. 2A).
Rotate the socket assembly until the ball drops and locks
into the hanger bracket screw.
10. Secure the safety cable to the building structure using spring
washer, flat washer, and wood screw provided (Fig. 2B)
NOTE:
Safety cable is required for all installations in Canada. Safety
cable is required for ceiling fan and light combinations over 35 lbs.
in both flush and downrod models in the United States.
WARNING:
Failure to properly install the cotter pin and/or
tighten the screws could result in the fan loosening and
possibly falling.