FR-W1811
Aviator Instructions
28
14. Troubleshooting
My Fan Will Not Start
CAUTION:
Make sure the main power is turned off!
1. Check main and branch circuit fuses or circuit breakers.
2. Check line wire connections to fan and switch wire connections
in the switch housings.
My Fan Is Noisy
1. Allow for 24-hour break-in period. Most noises associated with
a new fan will go away during this time period.
2. Check to make sure the screws which attached to the blades
(and blade arms when applicable) are tight.
3. Check to make sure all screws in motor housing are snug.
4. Make sure light cover is tightened and/or glass is snug.
5. Tighten the hanger bracket screws and make sure the
outlet box is secured.
6. Your wire connectors may be rattling against the fan’s canopy.
7. Make sure you have a cUL/UL approved outlet box and it is
installed correctly.
My Fan Is Wobbling
1. Tighten the setscrews in the downrod.
2. Make sure your hanger ball assembly is locked into place in
the hanger bracket.
3. Tighten the hanger bracket screws to the outlet box.
4. Make sure the fan blades are properly aligned and securely
fastened to the motor housing assembly/blade arms.
5. Make sure the gaps between the blades are evenly distributed
or make sure you are using an approved cUL/UL listed outlet
box and it is installed correctly.