background image

150 mm

2/10

Bei Montageplatte: Winkel MW-NZM 14 einsetzen

With Mounting plate: Fit MW-NZM 14 fixing angle

En cas de platine de montage: utiliser l'équerre MW-
NZM 14

Per istallazione sulla piastra di montaggio: applicare
la squadretta MW-NZM 14

Con placa de montaje: colocar el ángulo de fiajción
MW-NZM 14 

Монтажная плата: вставить угол MW-
NZM 14

u

 M8 

u

 50

90°

90°

90°

90° *)

*)  

max

 = 0.9 

u

  

n

 

Montage
Mounting
Montage
Montaggio
Montaje

Mонтаж

12/98 AWA 123-1455

Summary of Contents for NZM 14 Series

Page 1: ...ent Danger to life Only skilled or instructed persons may carry out the following operations Tension électrique dangereuse Seuls les personnes qualifiées et averties doivent exécuter les travaux ci après Pericolo di morte causa corrente elettrica Solo persone istruite e avvertite possono eseguire le operazioni di seguito riportate Corriente eléctrica Peligro de muerte El trabajo a continuación des...

Page 2: ...de montage utiliser l équerre MW NZM 14 Per istallazione sulla piastra di montaggio applicare la squadretta MW NZM 14 Con placa de montaje colocar el ángulo de fiajción MW NZM 14 Монтажная плата вставить угол MW NZM 14 4 u M8 u 50 90 90 90 90 max 0 9 u n Montage Mounting Montage Montaggio Montaje Mонтаж 12 98 AWA 123 1455 ...

Page 3: ...0 SW 19 50 Nm 800 A 1000 A 1250 A 1600 A 50 u 10 mm 2 u 40 u 10 mm 2 u 50 u 10 mm Anschluß Connection Raccordement Collegamento Conexión присоединеиние RG 1250 RG 1600 PTP PTP a b c a b 12 98 AWA 123 1455 ...

Page 4: ...w kA 0 3 s 20 off on I0 n x Iu Alarm 0 8 0 85 1 0 0 95 0 9 Ir nxI0 Irmv nxI0 Irm nxI0 5 10 30 20 15 2 4 10 8 100 150 300 250 I2 t 12 0 8 0 63 1 0 tr s 6xIr tv ms 0 n u u 0 8 0 63 1 0 6 u r r 5 s v r 30 r rm rmv r PUSH TO TRIP Test Iu A 1600 Icw kA 0 3 s 20 off on I0 n x Iu Alarm 0 8 0 85 1 0 0 95 0 9 Ir nxI0 Irmv nxI0 Irm nxI0 5 10 30 20 15 2 4 10 8 6 100 150 300 250 200 I2 t 3 12 6 9 0 8 0 63 1 0...

Page 5: ... 0 8 0 63 1 0 tr s 6xIr tv ms 0 1 0 4 100 800 200 400 0 2 0 3 300 TV tin ms Iin nxIu 5 l2 t l2 t ON 12 1 0 0 8 6 lu 1600 A l0 n u lu lr n u l0 3 lrm 1 0 u 12 u lu 19200 A 0 63 lrm TV NZM14 lin 0 1 0 4 lu tin 0 1 0 8 s Nur für 3poligen Schalter bei 4poligem Netz Anschluß für zusätzlichen Stromwandler Only with 3 pole switch with 4 pole network Connection for additional current converter Raccordemen...

Page 6: ... 2 u 0 75 2 5 mm2 6 10 mm PUSH TO TRIP Test Iu A 1600 Icw kA 0 3 s 20 off on I0 n x Iu Alarm 0 8 0 85 1 0 0 95 0 9 Ir nxI0 Irmv nxI0 Irm nxI0 5 10 30 20 15 2 4 10 8 6 100 150 300 250 200 I2 t 3 12 6 9 0 8 0 63 1 0 tr s 6xIr tv ms LUE 0 7 1 0 0 8 0 9 IL nxIr LUE NZM14 Ue V AC LU LU1 a b c d ALARM l 0 7 1 u lr nach after après dopo después de после Überlast Overload Surcharge Sopracarga Sobrecarga П...

Page 7: ...20 off on I0 n x Iu Alarm 0 8 0 85 1 0 0 95 0 9 Ir nxI0 Irmv nxI0 Irm nxI0 5 10 30 20 15 2 4 10 8 6 100 150 300 250 200 I2 t 3 12 6 9 0 8 0 63 1 0 tr s 6xIr tv ms 0 1 0 4 100 800 200 400 0 2 0 3 300 TV ti n ms Iin nxIu I RESET M Iin M NZM14 Ue V AC a b c d LED 1 1 2 3 LED 2 LED 3 12 98 AWA 123 1455 ...

Page 8: ...8 10 Sealed Push to trip I 0 I 0 a b c d a b c TEST 12 98 AWA 123 1455 ...

Page 9: ...70 X9 4 u M8 184 338 3P 4P 370 210 N 280 170 12 98 AWA 123 1455 10005954 0002 FD Printed in the Federal Republic of Germany Änderungen vorbehalten by 1998 Moeller GmbH 53105 Bonn 10 10 9 10 ...

Reviews: