Refrigerated display units are designed to keep pre-chilled food at a regulated serving 
temperature and are suitable for the display of most types of cold food. Designed to 
provide a chilled condition maintaining a safe and compliant temperature within. 
The Chilled display has an automatic defrost, and automatic condensate water 
evaporation system, eliminating the need to manually empty drip trays or onsite 
drainage.

Refrigerated Units

The controlled air temperature is factory set to operate between 2° and 5°.

  To enable automatic defrost, the13A plug must be constantly switched  

  on. The green switch can be switched off when the cooling is no longer  

  required, however, do not un-plug the unit from the mains power.

5: Operation model HH1C

 

The Display unit is controlled by a green neon on/off switch and a digital control. 

• 

Connect plug to 13-Amp socket and switch on at mains socket.  

• 

Power on with green illuminated Switch 

• 

Digital illuminates and controls the display temperature 

• 

Allow 30mins for the display too cool down before loading product 

• 

The controlled air temperature is factory set to operate between 2° and 5°  

• 

Defrost is factory set to operate automatically when required 

• 

When serving is complete all switches should be turned off.

Product should already be 5° or below before loaded into the display

                     These units are not designed to chill down hot food

7

Summary of Contents for Happy Host HH1A

Page 1: ...Manual 034 Issue 001 July 2021 Happy Host Operating Service Manual Heated Chilled Ambient Merchandisers...

Page 2: ...idity of 60 This unit is for indoor use only and has an IPX4 rating To ensure the best results from this unit please take the time to read and follow all safety installation and maintenance guidelines...

Page 3: ...nforming to code designation 60245 IEC 57 is supplied 2 Specification Model HH1H HH1C HH1A HH1S Weight kg 95 110 85 65 Electrical Supply 13amp 13amp 13amp 13amp Power Rating kw 2 85 1 0 0 036 0 018 Di...

Page 4: ...signed to be operated by suitably qualified persons It is the responsibility of the Supervisor or equivalent to instruct users provide suitable P P E show the mains isolating switch location and infor...

Page 5: ...er venting must be provided ensuring cool air from the room can be pumped in through the condensing coil and out the other side The hot air blown out from the opposite side must not be allowed to be s...

Page 6: ...s where there is high radiated heat e g direct sunlight room heaters or bright spot lights Do not install units in draughty conditions where the air movement is greater than 0 2mtr sec e g near doors...

Page 7: ...on The green switch can be switched off when the cooling is no longer required however do not un plug the unit from the mains power 5 Operation model HH1C The Display unit is controlled by a green neo...

Page 8: ...esigned to cook or heat up cold food Operation Switch on the unit using the green switch lovcated under the top sign For an even heat over all shelves the control knobs should be set as detailed in th...

Page 9: ...5 Operation model HH1H The rotary temperature control are located on the rear of the units The temperature can be set for each shelf 9...

Page 10: ...6 Operation model HH1A Ambient display units are perfect for attactively displaying foods such as muffins and cookies 10...

Page 11: ...ner panels can be removed to allow a deeper internal clean Ensure all panels and fixings are replaced after cleaning operation 4 Refrigeration compartment should be washed and then dried with a cloth...

Page 12: ...fat Ltd Bonnybridge FK4 2BS Scotland Scan the QR code below to visit the E R Moffat website for further information www ermoffat co uk 44 0 1324 812272 sales ermoffat co uk Thank you for choosing E R...

Reviews: