9.8 Other instruction parameters
85
9.8
Other instruction parameters
The
following
parameters
can
also
be
specified
in
parallel
table
entries, for special behaviours, as listed below. Instructions that use
the serial interface must be followed with a subsequent instruction
containing the
UPD
flag to activate them.
HOLD
Do not change the output (also known as a “nop” or “no operation”).
Intended to perform I/O operations or trigger a serial update (using
the
UPD
flag) without changing the
RF
.
REGx
Write
a
32-bit
value
directly
to
register
x
of
the
DDS
using
the
serial interface.
Provided for advanced functionality in consultation
with
the
AD9910
datasheet.
Requires
subsequent
entry
with
UPD
parameter to take effect.