Troubleshooting
Trouble
Digital display not illuminated.
Fan not operating (digital
display is illuminated).
Fan running continuously.
Poor evaporation of water.
Bottle empties completely.
Bottle continues to empty
after complete filling.
Bottle not emptying.
Probable Cause
• No Power.
• Power button has not been
depressed.
•
ROOM
humidity level is not
3% or more below
SET
humidity level.
• Reservoir is empty.
•
SET
humidity level is 65%.
•
ROOM
humidity level has not
reached 1% or more above
SET
humidity level.
•
CHECK FILTER
message
flashing.
• Mineral buildup on filter.
• This is normal for initial filling.
• Air is entering water bottle.
• Spring Valve Assembly
damaged or missing post
in bottom of base.
• Base full of water.
Remedy
• Check 120 volt power source.
• Press power button once to
turn on.
• Raise
SET
humidity level if
desired.
• Increase fan speed.
• Fill humidifier with water.
• A
SET
humidity percentage
of 65% operates fan
continuously. Adjust
SET
level between 25% - 60%.
• Continue to run until desired
humidity level is achieved.
This may take up to 48 hours
initially.
• Change to a fresh new
filter.
• NOTE: Local water varies
from area to area and under
certain conditions minerals
will build up more rapidly in
the filter.
• Refill bottle for maximum run
time.
• Check for leak in water bottle.
• Ensure fill valve position is
turned to closed and valve
has no interfering debris.
• Check orientation of bottle.
Reposition so that fill valve on
bottom of bottle is depressed
by post in bottom of base.
• The base will hold the
contents of water bottle (1.2
gallons). Continue to run
humidifier to deplete water
from base.