12
Troubleshooting
Trouble
Probable Cause
Remedy
Digital display not
illuminated.
•
No Power
Power button has not been
depressed.
•
Check 120 volt power source.
•
Press power button once to turn
on.
Fan not operating (digital
display is illuminated).
•
ROOM humidity level is not 3%
more below SET humidity level.
•
Reservoir is empty.
•
Raise SET humidity level if
desired.
•
Increase fan speed.
•
Fill humidifier with water.
Fan running
continuously.
•
SET humidity level is 65%.
•
ROOM humidity level has not
reached 1% or more above SET
humidity level.
•
A Set humidity percentage of 65%
operates fan continuously. Adjust
SET level between 25%-60%.
•
Continue to run until desired
humidity level is achieved. This
may take up to 48 hours initially.
Poor evaporation of
water.
•
CHECK FILTER message
flashing.
•
Mineral buildup on filter.
•
Change to a fresh new filter.
•
NOTE: Local water purity varies
from area to area.
Bottle empties
completely.
•
This is normal for
initial filling.
•
Refill bottle for maximum run time.
Bottle continues to empty
after complete filling.
•
Air is entering water bottle.
•
Check for leak in water bottle.
Bottle not emptying.
•
Spring Valve Assembly damaged
or missing post in bottom of base.
•
Base full of water.
•
Check orientation of bottle.
Reposition so that fill valve on
bottom of bottle is depressed by
post in bottom of base.
The base will hold the contents of
water bottle (1.25 gallons).
Continue to run humidifier to
deplete water from base.
Display blinks or fan
moves slightly when
humidifier is plugged in.
•
Normal
•
No action required.
Fan operating slower
than speed registered on
digital display
•
Humidifier in “DRY OUT MODE”.
•
Humidifier automatically switches
fan to (LOW) F1 when “F” and
alternating room humidity is
displayed.
Humidifier not shutting off
during “DRY OUT MODE”
•
Filter not dry.
•
During “DRY OUT MODE” the
humidifier will continue to run on
“LOW” speed as required for up to
2 hours or until the filter is
completely dry
.
Alternating “F” and room
humidity displayed.
•
Reservoir is empty.
•
Fill humidifier with water.
Alternating “CF” and
room humidity displayed.
•
Filter may be dirty.
•
Replace filter.
•
Unplug unit for 30 seconds and