background image

6. CONNECTION TO A DRAIN PIPE - LIFTING PUMP 

(optional) 

 

 
This dehumidifier can be connected directly with a fixed draining pipe; in this case, 
the  water  tank  must  be  removed  to  allow  for  the  connection  of  the  pipe  to  the 
connection fitting. 
 
For the connection, use one pipe provided with a ¾” female fitting at one end. 
In the machines with ball-cock, if the water tank is not fitted in, the machine will 
not work. 
 
Some  machines  have  a  switch  in  order  to  allow  the  functioning  without  water 
tanks,  in  other  machines  one  must  modify  the  tongue-shaped  device  placed 
near the ball-cock. 
 
In the machines with a tank in the front, a special fitting, which is supplied with 
the machine, must be placed on the right upper side of the water tank. 
 

 
 

 
 

 

Machines with condensed water lifting pumps 

 
This machine includes a condensed water lifting pump. This 
allows condensed water to be drained into a floor waste or similar. 
 
The pump will work automatically, controlled by a ball cock placed 
inside the pump. 
 
Before moving the machine, remember to purge water from water 
tank.  
 
If the pump cannot work correctly, the compressor stops and the 
green light turns on. In this case, check the pipe situation.   
 
Maximum head working pressure of the pump is about 3.5 
metres.

 

 

 

 
 

7.  PERIODICAL MAINTENANCE 

 
AIR FILTER CLEANING

 

 

The only required periodical maintenance is the cleaning of the filter 

once every month,

 or more often  if the enviroment 

is very dusty or the dehumidifier is working for many hours every day. 
 
Clean air filter by vacuuming or light hand cleaning. 
 
After a few years running, it may be necessary to clean the heat exchanger (condenser) by using compressed air.  
 
This operation must be done by a specialized technician. This cleaning will improve the performance and the long life of 
the machine. 

 
 
 
Note: You can acquire spare filters from your dealer's service. 
 
 
 

 
 
 
 
 
 
 
 

Moisture Cure Pty Ltd   (02) 6584 2511   www.moisturecurecommercial.com.au    sales@moisturecure.com.au

 

Summary of Contents for FDNF96

Page 1: ...FDNF96 DEHUMIDIFIER USER AND MAINTENANCE MANUAL Moisture Cure PO Box 5071 Port Macquarie New South Wales 2444 Australia ...

Page 2: ...onnected to power could cause water to come into contact with electrical parts It is therefore recommended to remove the plug from the socket before moving the dehumidifier Correct Distance this dehumidifier draws in the air from the back and lets out through the front side grill therefore the back panel which supports the air filter must be kept at a minimum distance of 15cm from the wall This de...

Page 3: ...uted by according to safety and electro magnetic compatibility to European Norms and Regulations MACHINES NORMS 2006 42 CE 17 05 2006 SECURITY REGULATIONS FOR LOW TENSION APPLIANCES 2006 95 CE 12 12 2006 ELECTROMAGNETIC COMPATIBILITY EMC 2004 108 CE 15 12 2004 It is hereby certified that this Dehumidifier conforms to the IEC Regulations CEI EN 60335 2 40 CEI EN 55014 1 55014 2 The machine is built...

Page 4: ...ower Consumption at 35 C 95 rh 1350 w Absorbed Current at 35 C 95 rh standard ver 7 2 A Locked Rotor Current LRA 29 Air Flow 1000 cm h Noise level at 3 meters 52 dB Refrigerant R134a Standard Defrosting Control System Electronic Hot Gas Defrosting Control System optional Electronic thermostat Water Tank Capacity 15 kg Continuous Drainage Pipe Connection 25mm Temperature Range standard version 7 35...

Page 5: ... M1 ev M2 fan Moisture Cure Pty Ltd 02 6584 2511 www moisturecurecommercial com au sales moisturecure com au LEGEND 1 COMPRESSOR 2 FAN MOTOR 3 ELECTRONIC CARD 4 HUMIDISTAT ELECTRONIC 5 MICRO SWITCH 6 ELECTRO VALVE 7 THERMOSTAT 8 HOUR COUNTER ...

Page 6: ...nser 3 Finally the fan motor 4 expels the air back into the room through the front grill panel The condensed water is collected in the tank 5 A micro switch 6 stops the machine when the water in the tank reaches the correct level by raising the water float lever The humidistat 7 starts the functioning of the dehumidifier when the humidity is higher than the preset level An electronic circuit 8 con...

Page 7: ...f power to the machine If the light WORKING is still off turn knob on the control panel clockwise until the light WORKING is ON The light DEFROST PAUSE will also switch on and after about 5 minutes the dehumidifier will start dehumidifying When the red light is ON ALARM the machine will not start one must check that the water tank is empty and that it is inserted correctly With machines that have ...

Page 8: ...ined into a floor waste or similar The pump will work automatically controlled by a ball cock placed inside the pump Before moving the machine remember to purge water from water tank If the pump cannot work correctly the compressor stops and the green light turns on In this case check the pipe situation Maximum head working pressure of the pump is about 3 5 metres 7 PERIODICAL MAINTENANCE AIR FILT...

Reviews: