TECHNICAL DATA
CONDENSED WATER AT DIFFERENT AMBIENT TEMPERATURE AND HUMIDITY CONDITIONS
10˚C
60%
10˚C
80%
15˚C
60%
15˚C
80%
20˚C
60%
20˚C
80%
25˚C
60%
25˚C
80%
27˚C
65%
27˚C
80%
30˚C
80%
32˚C
90%
10 l/d
18 l/d
15 l/d
23 l/d
20 l/d
28 l/d
25 l/d
35 l/d
28 l/d
39 l/d
52 l/d
62 l/d
TECHNICAL DATA
SAFETY
FRAL Company declines any responsibility for any danger or damage whenever this norm is not complied with.
Inspection:
After receiving the unit, immediately check its integrity. The unit left the factory in perfect condition; any eventual
damage must be questioned to the carrier and recorded on the Delivery Note before it is signed. Moisture Cure
must be informed within 7 days of the extent of damage.
The customer should prepare a written statement on any severe damage.
Lifting and Handling:
When unloading the unit, it is highly recommended to avoid any sudden moves in order to protect refrigerant
circuit, copper tubes or any other unit component.
When the unit is connected to the power supply, it must be in a vertical position and moving should be avoided.
Moving whilst connected to power could cause water to come into contact with electrical parts. It is therefore
recommended to remove the plug from the socket before moving the unit.
Unpacking:
When unpacking the unit, be careful not to damage it. The packaging is made up of different materials; wood,
paper, nylon, etc. It is a good rule to keep them separately and deliver to the proper collection centre in order to
reduce their environmental impact.
Location and Clearances:
Consideration must be given to the following points when determining the most suitable site for the unit
installation:
- location must ensure adequate air flow (no narrow spaces)
- location of power supply
- accessibility for servicing/maintenance and repair of the unit and/or its components
- floor loading strength and ability to support the operating weight of the unit
- possible objection to operating noise
Moisture Cure Pty Ltd (02) 65842511
www.moisturecure.com.au
sales@moisturecure.com.au
Power Consumption (at 27˚C, 65% rh)
700 w
Power Consumption (at 35˚C, 95% rh)
950 w
Absorbed Current (at 35˚C, 95% rh) standard ver.
4.4 A
Start Current Full Load Amp
20 A
Air Flow
600 cm/h
Noise level (at 3 meters)
49 dB
Refrigerant
R407c
Defrosting Control
Electronic
Continuous Drainage Pipe (male)
19mm
Temperature Range standard version
7-35˚ C
Relative Humidity Range
45-99%
Condensation Capacity (at 26˚C, 60% rh)
52 l/24 hr
Condensation Capacity (at 32˚C, 90% rh)
62 l/24 hr
Weight
48 kg
Dimensions
78cm x 68cm x 25cm