TECHNICAL DATA 

 
 

CONDENSED WATER AT DIFFERENT AMBIENT TEMPERATURE AND HUMIDITY CONDITIONS 

10˚C 
60% 

10˚C 
80% 

15˚C 
60% 

15˚C 
80% 

20˚C 
60% 

20˚C 
80% 

25˚C 
60% 

25˚C 
80% 

27˚C 
65% 

27˚C 
80% 

30˚C 
80% 

32˚C 
90% 

10 l/d 

18 l/d 

15 l/d 

23 l/d 

20 l/d 

28 l/d 

25 l/d 

35 l/d 

28 l/d 

39 l/d 

52 l/d 

62 l/d 

 

 
 

                               

TECHNICAL DATA

 

 

 

 
 

 
 
 

 
 

   
 
 

 
 

 

 
 

SAFETY 

 
FRAL Company declines any responsibility for any danger or damage whenever this norm is not complied with. 

 

Inspection: 

After receiving the unit, immediately check its integrity.  The unit left the factory in perfect condition; any eventual 
damage must be questioned to the carrier and recorded on the Delivery Note before it is signed.  Moisture Cure 
must be informed within 7 days of the extent of damage. 
The customer should prepare a written statement on any severe damage. 
 

Lifting and Handling: 

When  unloading  the  unit,  it  is  highly  recommended  to  avoid  any  sudden  moves  in  order  to  protect  refrigerant 
circuit, copper tubes or any other unit component. 
 
When the unit is connected to the power supply, it must be in a vertical position and moving should be avoided.  
Moving  whilst  connected  to  power  could  cause  water  to  come  into  contact  with  electrical  parts.    It  is  therefore 
recommended to remove the plug from the socket before moving the unit.   
 

Unpacking: 

When  unpacking  the  unit,  be  careful  not  to  damage  it.  The  packaging  is  made  up  of  different  materials;  wood, 
paper, nylon, etc.  It is a good rule to keep them separately and deliver to the proper collection centre in order to 
reduce their environmental impact. 
 

Location and Clearances: 

Consideration  must  be  given  to  the  following  points  when  determining  the  most  suitable  site  for  the  unit 
installation: 
- location must ensure adequate air flow (no narrow spaces) 
- location of power supply 
- accessibility for servicing/maintenance and repair of the unit and/or its components 
- floor loading strength and ability to support the operating weight of the unit 
- possible objection to operating noise 
 
 
 

Moisture Cure Pty Ltd    (02) 65842511   

www.moisturecure.com.au

    

sales@moisturecure.com.au

 

Power Consumption (at 27˚C, 65% rh) 

700 w 

Power Consumption (at 35˚C, 95% rh) 

950 w 

Absorbed Current (at 35˚C, 95% rh) standard ver. 

4.4 A 

Start Current Full Load Amp 

20 A 

Air Flow 

600 cm/h 

Noise level (at 3 meters) 

49 dB 

Refrigerant  

R407c 

Defrosting Control 

Electronic 

Continuous Drainage Pipe (male) 

19mm 

Temperature Range standard version 

7-35˚ C 

Relative Humidity Range 

45-99% 

Condensation Capacity (at 26˚C, 60% rh) 

52 l/24 hr 

Condensation Capacity (at 32˚C, 90% rh) 

62 l/24 hr  

Weight 

48 kg 

Dimensions 

78cm x 68cm x 25cm 

Summary of Contents for FRAL FDW62

Page 1: ...Dehumidifier FDW62 Fan Coil Type USER AND MAINTENANCE MANUAL Moisture Cure Pty Ltd PO Box 5071 Port Macquarie New South Wales 2444 Australia Telephone 02 65842511 www moisturecure com au sales moisturecure com au ...

Page 2: ...Moisture Cure Pty Ltd 02 65842511 www moisturecure com au sales moisturecure com au ...

Page 3: ...erefore recommended to remove the plug from the socket before moving the unit Unpacking When unpacking the unit be careful not to damage it The packaging is made up of different materials wood paper nylon etc It is a good rule to keep them separately and deliver to the proper collection centre in order to reduce their environmental impact Location and Clearances Consideration must be given to the ...

Page 4: ...o that of the unit reported on the label in the front panel of the unit Power connections must consist of a 3 wire cable phase cable active neutral wire and ground cable earth The line voltage fluctuations must not be more than 5 of the nominal value MAINTENANCE Moisture Cure Pty Ltd 02 65842511 www moisturecure com au sales moisturecure com au The outside of the unit must not be cleaned using wat...

Page 5: ...d stay on Otherwise the electronic card is defective Central LED on Compressor defective Replace defective board Moisture Cure Pty Ltd 02 65842511 www moisturecure com au sales moisturecure com au Turn ON the unit After the unit is connected to the power press ON OFF switch lower left side and the unit will start The WORK LED will indicate that the unit is working Whilst the unit is running the WO...

Page 6: ...Moisture Cure Pty Ltd 02 65842511 www moisturecure com au sales moisturecure com au ...

Reviews: