LW005-MP
10 www.mokosmart.com
LW005-MP will report
Electrical Payload
periodically, which contains voltage, current, frequency,
active power and power factor.
6.6 Energy Monitoring
The plug can record daily /historical total energy data locally, and the measuring accuracy
can reach ±0.5%.
LW005-MP will report
Energy Payload
periodically, which contains historical total energy and
energy data of the previous hour.
6.7 Power Consumption Indicator
The power indicator can be changed to different colors according to the active power of the
connected loads. The different colors of the indicator represent different power levels, which is
convenient for users to intuitively and quickly capture the changes in load power.
6.8 Over-voltage/Sag-voltage/Over-current/Over-load Protection
The plug has multiple protection mechanisms. When it detects that the voltage/current/power of
the connected load is out of the safe range, the plug will automatically turn off, and the indicator
will flash red, and report
Over-voltage Payload
/
Sag-voltage Payload
/
Over-current Payload
/
Over-
load Payload
to LoRaWAN server.
⚫
Over-voltage protection: When the plug detects that the measured voltage exceeds the over-
voltage threshold for a period of time, it will automatically turn off.
⚫
Sag-voltage protection: When the plug detects that the measured voltage lows the sag-
voltage threshold for a period of time, it will automatically turn off.
⚫
Over-current protection: When the plug detects that the measured current exceeds the
current threshold for a period of time, it will automatically turn off.
⚫
Over-load protection: When the plug detects that the measured power exceeds the power
threshold for a period of time, it will automatically turn off.
6.9 Load Work State Detection
When the plug detects that the load starts/stops working, it will immediately report a notification
to the server. The user can receive the notification from LoRaWAN server, and know the working
status of the load at any time.
6.10 Restore to Factory Setting
There are two ways to restore to factory setting:
1.Through the physical button, press and hold the button for 10 seconds, the plug will restore to
factory setting.
2.User can send LoRaWAN downlink commands to make the plug restore to factory setting via
LoRaWAN server.