Figure 23: LED schematic
Figure 24: LED on board
6 Quick Start
MKL62ST_DT supports two different working modes: AT command mode and host mode. The
two working modes will be introduced separately below.
6.1 AT Command Mode
The purpose of AT Command mode is to help user get familiar with AT commands of MKL62BA
module.
6.1.1 Quick Start AT Command Debugging
Check the UART interface and make sure that the USB UART is directly connected to the
MKL62BA module UART. Install the LoRa antenna in the following way. You also can use
your own antenna with the IPEX connector to install it directly on the MKL62BA IPEX
connector.
Connect the USB cable to the computer, LED4 will be solid blue to indicate a successful
power connection.
Open the SerialNet data debugger software and set the COM, the following takes SSCOM as
an example:
1. Set ComNum: select COM with silicon Labs CP210x USB to UART Bridge.
2. Set COM parameters: set according tp the default values in the MKL62BA module.
Baud rate: 9600
Data bits: 8
Stop bits: 1
Parity: None
Flow control: None