6.2.1 Operation Instruction
Check and install the jumper caps according to the following figure. You can directly install
your own IPEX external antenna to the IPEX connector, or you can connect the IPEX socket
according to the following figure and install the SMA antenna provided by MOKO. And plug
in the USB to power on the development board and the blue LED will light on.
Get the join network parameters of MKL62BA.The default parameters are as follows. You
can also use AT command to get and set the parameters. Please refer to the operation in
chapter 6.1.1.
Register the module as an OTAA end device in the LoRa server and ensure that all the
parameters are correct.
After registering the device in the LoRa sever, a join network request from MKL62ST-DT will
be send automatically.
After successfully joining the network, the user can see on the server that the temperature
and humidity sensor data are reported every 10 seconds.
NO.
Type
Default value
1
Join Mode
OTAA
2
DevEUI
BLE MAC+ FFFF,
3
AppEUI
70B3D57ED0026B87
4
AppKey
2b7e151628aed2a6abf7158809cf4f3c
5
DevAddr
The last four bytes of MAC address
6
AppSKey
2b7e151628aed2a6abf7158809cf4f3c
7
NwkSkey
2b7e151628aed2a6abf7158809cf4f3c
8
Region
US915
9
Device Type ClassA