Example:
Original: Scan interval: 0.1s
Measurement duration: pre-trigger 4 s; post-trigger 6s (measurement buffer
full)
New scan interval: 0.05s
Makes: pre-trigger 2s; post-trigger 3s (measurement buffer full)
The triggered measure cycle is functionally identical with the triggered
measurements, but the trigger is re-activated after successful measurement
so as to start a new measurement once the trigger conditions occur again.
7.14.2 Trigger Tab
System variables, system events and system alarms can be used as trigger
events.
Variable-Trigger
System variables that can be configured as triggers are created in the
variables monitor. These variable groups are available in the software
oscilloscope in the same grouping as configured in the variables monitor. All
types of system variables that can be recorded can also be used as trigger
variables.
If a numerical system variable has been selected as trigger, a trigger
threshold must be entered and an excess / undershoot must be specified at
which the measurement shall be started. For a Boolean variable the Edge
must be selected.
Measure Parameter Tab - continued
7-24
E-Drive Controller User Manual (with Pendant HMI)
SCREEN FUNCTIONALITY