4. Select a Pick Order option.
Click Standard to pick from regions in straight columns from the source receptacle,
such as A1 to A8, B1 to B8, and so on.
Click Plating Order to pick from square blocks of eight regions, such as A1 to B4, A5 to
B8, and so on. This is similar to the picking order used for a QPix 460 System plating
process. See
5. Under Destination Microplate Template, click Edit to define the wells to dip. Skip wells to
use as blank or control wells. The defined template is used for all the destination plates
during the picking routine.
To skip a well, click the well. Wells to skip display in light blue.
To skip multiple contiguous wells, right-click and drag across the wells.
To dip a well that you select to skip, click the well again. Wells to dip display in red.
After you define the wells to dip or skip, click Exit.
6. Click Next to define the picking head and the Sanitise profile.
Selecting the Head and Sanitizing Options
To select the head and sanitizing options:
1. In the Head and Sanitise window, from the Picking Head list, select the head to use for the
picking routine.
2. In the Pin Columns (Rows) Before Inoculation list, select the number of pins to use to pick in
each column or row before transferring the picked colonies to the destination plate.
For the fastest transfer rate, select All to use all available picking pins to pick colonies
before inoculating the destination plate.
For smaller picking groups, the available selections depend on the Deposit Order selection
made in the Destination/Source Options window.
If you select By Columns, you can pick colonies using from 1 to 11 columns.
If you select By Rows, you can pick colonies using from 1 to 7 rows.
To run the wash routine from the Sanitise profile after each partial pick and inoculation,
select the Wash Between Partial Inoculation check box. Clear this check box to wait until all
pins are used for picking and inoculation before running the wash routine.
3. In the Destination field, enter a value for the distance in millimeters above the bottom of the
destination plate wells to dip the pins for the inoculation.
If you select Make Copy for the destination plate, enter a value for the copy.
4. From the Sanitise Profile list, select the Sanitise profile to use for the picking routine.
If the available profiles are not suitable for the regional picking routine, exit the regional
picking process and create a new Sanitise profile. See
Creating and Editing Sanitise Profiles
.
5. Click Next to view a summary of the settings.
Summary of Contents for QPix 450
Page 1: ...5031498 G August 2022 QPix 450 or QPix 460 Colony Picking System User Guide ...
Page 6: ...QPix 450 or QPix 460 Colony Picking System User Guide 6 5031498 G ...
Page 22: ...QPix 450 or QPix 460 Colony Picking System User Guide 22 5031498 G ...
Page 56: ...QPix 450 or QPix 460 Colony Picking System User Guide 56 5031498 G ...
Page 102: ...QPix 450 or QPix 460 Colony Picking System User Guide 102 5031498 G ...
Page 158: ...QPix 450 or QPix 460 Colony Picking System User Guide 158 5031498 G ...
Page 176: ...QPix 450 or QPix 460 Colony Picking System User Guide 176 5031498 G ...
Page 218: ...QPix 450 or QPix 460 Colony Picking System User Guide 218 5031498 G ...
Page 226: ...QPix 450 or QPix 460 Colony Picking System User Guide 226 5031498 G ...
Page 250: ...QPix 450 or QPix 460 Colony Picking System User Guide 250 5031498 G ...
Page 256: ...QPix 450 or QPix 460 Colony Picking System User Guide 256 5031498 G ...