background image

Hand Crimp Tool for 2.50mm (.098”) / 3.00mm (.118”) Pitch Wire-to-Board Female Crimp Terminal 

Doc No: ATS-638235200 

Release Date: 06-17-10 

UNCONTROLLED COPY

 

Page 2 of 7 

Revision: A 

Revision Date: 06-17-10 

 

CONDITIONS: 

 
After crimping, the conductor profiles should measure the following. 

 

Conductor Crimp 

Wire Size 

Height 

Width (Ref.) 

Profile 

Terminal Series No 

AWG  mm

2

 

mm 

In. 

mm 

In. 

16  18  20 

16 

1.30  1.32-1.42  .052-.056  1.90  .075 

 

 

18 

0.80  1.09-1.19  .043-.047  1.90  .075 

 

 

50350 

20 

0.50  0.99-1.09  .039-.043  1.80  .071 

 

 

 

Insulation Crimp 

Wire Size 

Max Height (Ref.)  Width (Ref.) 

Pull Force 

Minimum 

Terminal Series No 

AWG  mm

2

 

mm 

In. 

mm 

In. 

Lb. 

16 

1.30 

3.20 

.126 

2.30  .091  127.4  28.6 

18 

0.80 

3.00 

.118 

2.30  .091 

88.2  19.8 

50350 

20 

0.50 

2.60 

.102 

2.20  .087 

58.8  13.2 

 

OPERATION 

 

CAUTION: 

Install only Molex terminals listed above with this tool.  Do not crimp hardened objects as damage can 

occur to the tool or die. 

 
 
Open the tool by squeezing the handles together.  At the end of the closing stroke, the ratchet mechanism will 
release the handles and the hand tool will spring open.  See Figure 1. 
 

Crimping Terminals 

 
1.

 

Select the desired terminal listed 
from the preceding charts.  Then 
install it in the proper locator (See 
chart above and see Locator 
Installation on page 5). 

2.

 

Make sure the center of the locator is 
in the down position.  With the 
locator attached, push the locator 
button on the back of the hand tool to 
bring the locator forward through the 
tooling.  See Figure 2. 

 
 
 
 
 
 

SQUEEZE 
HANDLES 

TOGETHER 

HANDLE WILL 
SPRING OPEN 

Figure 1 

LOCATOR 

IN DOWN 
POSTION 

PUSH ON THE 

LOCATOR BUTTON 

Figure 2 

Summary of Contents for 63823-5200

Page 1: ...A IPCA620 Class 2 compliant as indicated This tool is RoHS compliant however RoHS compliant is not required SCOPE Products 2 50mm 098 3 00mm 118 Pitch Wire to Board Female Crimp Terminal 16 20 AWG Ter...

Page 2: ...2 19 8 50350 20 0 50 2 60 102 2 20 087 58 8 13 2 OPERATION CAUTION Install only Molex terminals listed above with this tool Do not crimp hardened objects as damage can occur to the tool or die Open t...

Page 3: ...until the first ratchet position engages See Figure 4 6 Insert the properly stripped wire through the terminal and against the wire stop See Figure 5 7 Crimp the terminal by squeezing the tool handle...

Page 4: ...ull away from the hand tool The top locator hooks should slip out of the top slots easily See Figure 7A 4 To reinstall the new locator make sure the hand tool is in the open position 5 Press the red i...

Page 5: ...oil Do not oil excessively The tool was engineered for durability but like any other equipment it needs cleaning and lubrication for a maximum service life of trouble free crimping Light oil such as 3...

Page 6: ...damaged tools This tool is designed for hand use only Any clamping fixturing or use of handle extensions voids this warranty CAUTION Molex crimp specifications are valid only when used with Molex term...

Page 7: ...17 10 UNCONTROLLED COPY Page 7 of 7 Revision A Revision Date 06 17 10 RATCHET RELEASE LEVER 2 Figure 13 1 3 PARTS LIST Item Number Order Number Description Quantity REF 63823 5200 Hand Crimp Tool Fig...