Tool Kit for CSP 6.3 Receptacle Terminal
Doc No: ATS-6382557HM Release Date: 07-31-12
UNCONTROLLED COPY
Page 3 of 8
Revision: A
Revision Date: 07-31-12
ANVILS
POWER
CRIMP
HEAD
Figure 1
PUNCHES
M4 X 10 LONG
BHCS
M4 X 18 LONG
BHCS
SWING
LOCATOR
OPEN
PRESS DOWN
ON THE BRASS
PIVOT SHAFT
LIFT UP ON
THE LOCATOR
Figure 2
Figure 4
SWING OPEN
TERMINAL
PUSH HERE TO
OPEN WIRE STOP
LOCATOR
TERMINAL
IN PLACE
LOCATOR LATCH
IN OPEN POSITION
INSTALLATION
To install the Tool Kit into the Power Crimp Head follow the steps below:
Anvils and Punches Installation
1.
Insert the Anvils into the bottom slots of the nest. Install the M4 x 10 long BHCS and tighten in place.
2.
Insert the Punches into the top slots of the nest. Install the M4 x 18 long BHCS and tighten in place. See
Figure 1.
Locator Installation and Removal
Follow the steps below to install or replace the locator. See Figure 2.
To install the locator
1.
Position the locator with the hole over the brass pivot shaft and snap it into place.
To remove the locator
1.
Open the crimp hand tool.
2.
Swing the existing locator open and away from the hand tool.
3.
Firmly press down on the
brass pivot shaft with your
thumb, while pulling the
locator up. Slip the locator
off the top of the brass pivot
shaft.
OPERATION
Open the tool by squeezing the
handles together, at the end of
the closing stroke, the ratchet
mechanism will release the
handles, and the hand tool will
spring open.