background image

Hand Crimp Tool for Board-In Crimp Terminals 

Doc No: ATS-6382569HM 

Release Date: 07-25-12 

UNCONTROLLED COPY

 

Page 2 of 6 

Revision: A 

Revision Date: 07-25-12 

 

Insulation Crimp Note

Due to the terminal’s insulation grip design and/or 
insulation diameter range, this tool uses “overlap” 
form geometry in the insulation punch. This produces 
an overlap insulation crimp (A620 – compliant). While 
the insulation punch profile may appear “lopsided”, 
this is a normal condition for this tool. See figure to 
the right. (Some tools with multiple crimp pockets may 
not have the “overlap” profile on all pockets). 
 

CRIMP SPECIFICATIONS: 

 
After crimping, the crimp profiles should measure the following. 

Terminal Series No. 

Wire Size 

Conductor Crimp 

Profile 

Height 

Width (Ref.) 

AWG  mm² 

mm 

In. 

mm 

In. 

A (24)  B (22)  C (20) 

50097 

20 

0.50  0.92-1.02  .036-.040  1.30-1.40  .051-.055 

 

 

22 

0.35  0.84-0.89  .033-.035  1.30-1.40  .051-.055 

 

 

24 

0.20  0.77-0.82  .030-.032  1.30-1.40  .051-.055 

 

 

 

Terminal Series No. 

Wire Size 

Insulation Diameter   

Insulation Crimp Maximum 

Pull Force 

Minimum 

Height (Ref.) 

Width (Ref.) 

AWG  mm² 

mm 

In. 

mm 

In. 

mm 

In. 

Lb. 

50097 

20 

0.50 

1.40-1.90 

.055-.075 

1.90 

.075 

1.90 

.075 

58.8  13.21 

22 

0.35 

1.40-1.90 

.055-.075 

1.90 

.075 

1.90 

.075 

39.2 

8.81 

24 

0.20 

1.40-1.90 

.055-.075 

1.90 

.075 

1.90 

.075 

29.4 

6.61 

To Achieve IPC-A-620 Class 2 Crimps, the following over-all wire insulation diameter ranges are recommended: 

Profile A (24): 1.40-1.90mm (.055-.075 in.) 
Profile B (22): 1.40-1.60mm (.055-.063 in.) 
Profile C (20): 1.60-1.90mm (.063-.075 in.) 

 

Tool Qualification Notes: 

1.

 

Pull Force should be measured with no influence from the 
insulation crimp. 

2.

 

The above specifications are guidelines to an optimum 
crimp. 

 

OPERATION 

 
Open the tool by squeezing the handles together, at the end of 
the closing stroke, the ratchet mechanism will release the 
handles, and the hand tool will spring open. 
 

Crimping Terminals 

1.

 

With the hand tool in the open position, pivot the terminal 
locator open by pulling up on the locator knob and lift the 
wire stop blade up.  See Figure 1. 

2.

 

Insert the terminal into the correct profile until the terminal is fully seated and stops.  Make sure the wire 
stop blade is fully seated on the terminal behind the conductor grip section. 

OVERLAP 

INSULATION 

CRIMP 

OVERLAP FORM GEOMETRY 

ANVIL 

PUNCH 

WIRE 

TERMINAL 

SEATED IN 

LOCATOR 

LOCATOR 

OPEN 

Figure 1 

HAND TOOL 

OPEN 

Summary of Contents for 63825-6900

Page 1: ... Crimp Head is removable and can be use in the Air Powered Tool Order No 63816 0100 accompanied by Air Powered Crimp Adapter Order No 63816 0700 Can also be used in the Battery Powered Tool Order No 63816 0200 110 V or 63813 0250 220 V accompanied by Battery Powered Crimp Adapter Order No 63816 0600 SCOPE Products 2 50mm Pitch Board In Crimp Terminal Male 20 24 AWG Terminal Series Terminal Order N...

Page 2: ... mm In mm In mm In N Lb 50097 20 0 50 1 40 1 90 055 075 1 90 075 1 90 075 58 8 13 21 22 0 35 1 40 1 90 055 075 1 90 075 1 90 075 39 2 8 81 24 0 20 1 40 1 90 055 075 1 90 075 1 90 075 29 4 6 61 To Achieve IPC A 620 Class 2 Crimps the following over all wire insulation diameter ranges are recommended Profile A 24 1 40 1 90mm 055 075 in Profile B 22 1 40 1 60mm 055 063 in Profile C 20 1 60 1 90mm 063...

Page 3: ...fully closed Note To maintain good brush control and a consistent bell mouth the crimping instructions must be followed Terminal Locator Replacement Change Over This section describes the procedure for changing locators Removal 1 With the tool in the open position pivot the terminal locator outward 2 Remove the M4 BHCS See Figure 4 Installation 1 Place the proper locator on the hand tool Install t...

Page 4: ...made of the best quality materials All vital components are long life tested All tools are warranted to be free of manufacturing defects for a period of 30 days Should such a defect occur we will repair or exchange the tool free of charge This repair or exchange will not be applicable to altered misused or damaged tools This tool is designed for hand use only Any clamping fixturing or use of handl...

Page 5: ...struction and without first reading and understanding the instructions in the proper Manual or Specification Sheet See Chart below for the correct Manual or Specification Sheet WARNING NEVER install tooling or service this tool while it is into any power source Disconnect the power by unplugging or turn off the Actuator from its power source CAUTION Keep fingers away from the crimping area when op...

Page 6: ...EVER HANDLE SPRING CRIMPING SPRING 2 LOCATOR 2 1 Figure 9 M4 X 6mm LONG BHCS 3 4 6 5 PARTS LIST Hand Crimp Tool 63825 6900 Item Order Number Description Quantity 1 63825 6970 Modular Crimp Head 1 Ref 2 63816 0050 Hand Crimp Frame Short 1 Ref 3 63825 6975 Locator 1 4 63816 0001 Locking Pin 2 5 63600 0525 Handle Spring 1 6 63600 0520 Crimping Spring 2 http www molex com ...

Reviews: