AT-200 Air-Powered Crimp Tool
Doc No: TM-192790001
Release Date: 07-01-02
UNCONTROLLED COPY
Page 9 of 20
Revision: G
Revision Date: 01-17-14
SAFETY
(
LOCKED
)
SAFETY ON TRIGGER
(UNLOCKED)
BASE
CRIMP TOOL
PUSH IN
CRIMP TOOL
Figure 2-3
SAFETY
(LOCKED)
SAFETY ON TRIGGER
(UNLOCKED)
CRIMP TOOL
SQUEEZE HERE
Figure 2-4
SQUEEZE HERE
Note
: Always use the safety or disconnect air supply when changing crimping heads.
2.2 Operation
1.
For the proper crimping head, use the tool order number specified on the label of connector container.
2.
Strip the proper wire to the length specified on the label of connector container or on the air powered crimp
tool head specification sheet.
3.
Load the desired terminal into the crimp nest. Insert the properly stripped wire into the terminal barrel.
For the Bench Mount Application
1.
Slide the Air Powered Crimp Tool into the base. The safety will bump against the base top and the trigger on
the crimp tool will unlock. See Figure 2-3.
CAUTION:
Air-Powered Crimp Tool will not operate if the safety in trigger is locked.
1.
Push on the wire to assure it is fully seated in the terminal. Cycle the tool by activating the foot pedal.
2.
Remove the crimped terminal. Inspect for proper crimp location.
For Hand Held Application
3.
Push on the wire to assure it is fully seated in the terminal.
4.
Activate the AT-200 Crimp Tool by sliding the safety on the trigger forward using your thumb and then
squeezing the trigger until the crimp jaws are fully closed. See Figure 2-4.
5.
Release the trigger and remove the crimped terminal. Inspect for proper crimp location.