AT-2212 Air Crimp Tool Head
Doc No: ATS-640053600
Release Date: 06-24-03
UNCONTROLLED COPY
Page 2 of 8
Revision: B
Revision Date: 09-30-05
OPERATION
Refer to the instruction manual for the 19279-0001 (AT200) for
mounting this crimp tool head.
Wire Preparation
Pre-twisted wire not required for OEM applications. For Solid (OEM only) strip leads to 3/8 of an inch. Insert into
connector and crimp.
For stranded wire strip leads to approximately 3/4 of an inch. Twist the wire combination even and tight. Trim
stripped pre-twisted area to 3/8 of an inch and insert into connector and crimp. For more information follow the
Quality Crimping Handbook.
CHART 1
Wire Combinations for Nylon
Insulated Closed End Connectors
Part No. 191600009 (NC-2212)
Wire Type
Wire Gauge (AWG)
Rating
14 16 18 20 22
Stranded or Solid
1
1
UL & CSA
Stranded or Solid
1
1
UL & CSA
Stranded or Solid
1
2
UL & CSA
Stranded or Solid
1
1
1
UL & CSA
Stranded or Solid
1
1
2
UL & CSA
Stranded or Solid
1
1
1
UL & CSA
Stranded or Solid
1
1
2
UL & CSA
Stranded or Solid
1
1
3
UL & CSA
Stranded or Solid
1
1
UL & CSA
Stranded or Solid
1
2
UL & CSA
Stranded or Solid
1
3
UL & CSA
Stranded or Solid
1
1
UL & CSA
Stranded or Solid
1
2
CSA
Stranded or Solid
1
3
CSA
Stranded or Solid
1
4
CSA
Stranded or Solid
1
1
1
1
CSA
Stranded or Solid
3
UL & CSA
Stranded or Solid
2
UL & CSA
Stranded or Solid
2
1
UL & CSA
Stranded only
2
2
UL & CSA
Stranded or Solid
2
1
UL & CSA
Stranded or Solid
2
2
UL & CSA
Stranded or Solid
2
1
UL & CSA
Stranded or Solid
2
2
UL & CSA
Stranded or Solid
2
3
UL & CSA
Stranded or Solid
2
1
1
UL & CSA
Stranded or Solid
2
1
1
UL & CSA
Stranded or Solid
2
1
1
UL & CSA
Stranded or Solid
1
1
2
UL & CSA
Stranded or Solid
1
1
UL & CSA
Stranded or Solid
1
1
UL & CSA
Stranded or Solid
1
2
UL & CSA
Stranded or Solid
1
3
UL & CSA
Stranded or Solid
1
1
UL & CSA
Wire Combinations for Nylon
Insulated Closed End Connectors
Part No. 191600009 (NC-2212)
Wire Type
Wire Gauge (AWG)
Rating
14 16 18 20 22
Stranded or Solid
1
2
UL & CSA
Stranded or Solid
1
3
UL & CSA
Stranded or Solid
1
4
UL & CSA
Stranded or Solid
1
1
UL & CSA
Stranded or Solid
1
2
UL & CSA
Stranded or Solid
1
3
UL & CSA
Stranded or Solid
1
4
UL & CSA
Stranded or Solid
1
5
UL & CSA
Stranded or Solid
1
2
1
UL & CSA
Stranded or Solid
1
2
1
UL & CSA
Stranded or Solid
1
2
2
UL & CSA
Stranded or Solid
1
1
1
UL & CSA
Stranded or Solid
1
2
1
UL & CSA
Stranded or Solid
1
1
2
UL & CSA
Stranded Only
5
UL only
Stranded or Solid
4
UL & CSA
Stranded or Solid
4
1
UL & CSA
Stranded or Solid
4
1
UL & CSA
Stranded or Solid
3
UL & CSA
Stranded or Solid
3
1
UL & CSA
Stranded or Solid
3
2
UL & CSA
Stranded or Solid
3
1
UL & CSA
Stranded or Solid
3
2
UL & CSA
Stranded or Solid
3
3
UL & CSA
Stranded or Solid
3
1
1
UL & CSA
Stranded or Solid
2
UL & CSA
Stranded or Solid
2
1
UL & CSA
Stranded or Solid
2
2
UL & CSA
Stranded or Solid
2
3
UL & CSA
Stranded or Solid
2
1
UL & CSA
Stranded or Solid
2
2
UL & CSA
Stranded or Solid
2
3
UL & CSA
Stranded or Solid
2
1
1
UL & CSA
Stranded or Solid
2
2
1
UL & CSA
3/8 “