MagKrimp™ Hydraulic Head Crimper
Doc No. TM-190780422
Release Date: 03-28-14
UNCONTROLLED COPY
Page 4 of 22
Revision: A
Revision Date: 03-28-14
WARNING
WARNING
Never
use this tool without guards or safety devices
that are intended to prevent hands from remaining
in the die space.
Failure to observe this warning could result
In severe injury or death.
Do not use
compressed air to clean
this equipment.
The forces created by compressed
air can force debris into the tool.
Failure to observe these precautions may
result in injury or property damage.
Air
Hydraulic
Pump
WARNING
Pump
WARNING
Hand/Foot Operated
Maximum Capacity: 10,000 PSI
Before operating the hydraulic pump, all hose
connections must be tightened with proper tools.
Do not
over-tighten. Connections need only be
tightened securely and leak-free. Over-tightening
may cause premature thread failure or may cause
high-pressure fittings to split at pressures lower
than their rated capacities
Should a hydraulic hose ever rupture, burst, or need
to be disconnected, immediately shut off the pump
and shift the control valve twice to release all pressure.
Never
attempt to grasp a leaking hose under pressure
with your hands. The force of escaping hydraulic fluid
could cause serious injury.
Do not
subject the hose to potential hazard such as fire,
extreme heat or cold, sharp surfaces, or heavy impact.
Do not
allow the hose to kink, twist, curl, or bend so
tightly that the oil flow within the hose is blocked or
reduced. Periodically inspect the hose for wear because
any of these conditions can damage the hose and
possibly result in personal injury.
Do not
use the hose to move attached equipment.
Stress may damage hose and possibly cause personal
injury.
Hose material and coupler seals must be compatible
with the hydraulic fluid used. Hoses must not encounter
corrosive materials such as creosote-impregnated
objects and some paints. Consult the manufacturer
before painting a hose.
Never
paint the couplers. Hose deterioration due to
corrosive materials may result in possible personal injury
Do not
exceed the PSI hydraulic rating noted
on the pump nameplate or tamper with the
internal high-pressure relief valve.
Creating pressure beyond rated capacities
may result in personal injury.
Before replenishing the oil level, retract the
system to prevent overfilling the pump reservoir.
An overfill may cause personal injury due
to excess reservoir pressure created when
cylinders are retracted.
Cylinder
WARNING
Do not
exceed rated capacities of the cylinders.
Excess pressure may result in personal injury.
Do not
set poorly balanced or off- center
loads on a cylinder. The load may tip and
cause personal injury.
Air
Supply
WARNING
Shut off and disconnect the air supply when
the pump is not in use or before breaking
any connection in the system.