PRODUCT APPLICATION SPECIFICATION
THIS DOCUMENT CONTAINS INFORMATION THAT IS PROPRIETARY TO MOLEX ELECTRONIC TECHNOLOGIES, LLC AND SHOULD NOT BE USED WITHOUT WRITTEN PERMISSION
REVISION
DESCRIPTION
REVISED
APPLICATION SPECIFICATION FOR
MICRO-LOCK PLUS 2.0 SINGLE ROW
CHANGE NO.
682239
REVISED BY
SOKUMURA01
DATE
2021/02/09
DOC TYPE
DOC TYPE DESCRIPTION
DOC PART
SERIES
REV APPR BY AIDA
DATE
2022/06/30
PS
APPLICATION SPECIFICATION WORD
A03
505570
INITIAL RELEASE
CUSTOMER
DOCUMENT NUMBER
REVISION
SHEET
INITIAL DRWN KUSATO
DATE
2016/04/20
GENERAL MARKET
5055700001
E
13
OF
49
INITIAL APPR
TKANEKO
DATE
2016/04/21
PROCEDURE: 2090580010-ES TEMPLATE: 2090580010-PAS-A4 REVISION: A1
【
6. Harness processing (crimping wire insertion method in receptacle housing)
】
Insertion procedure and instructions (
※
) of the crimping wire are shown as follows:
6-1. Insertion crimping wire
1.
Hold receptacle housing by pinching right and left side.
2.
Please hold the cable at about 10mm away from the crimp-end with a finger lightly.
※
If you hold the wire at a position distant from terminal, wires will be easily bent and it may be difficult to insert.
※
Distance value depends on wire gauge, UL, etc. Please confirm with the wire that you chose before using.
3.
Hold the terminal lance part toward center of receptacle housing and insert terminal slowly and straightly
till the tip of terminal touches housing (with force of around 1.6
~
2.4N).
(Fig.6-1)
Fig.6-1
Instruction
10 mm