PRODUCT APPLICATION SPECIFICATION
THIS DOCUMENT CONTAINS INFORMATION THAT IS PROPRIETARY TO MOLEX ELECTRONIC TECHNOLOGIES, LLC AND SHOULD NOT BE USED WITHOUT WRITTEN PERMISSION
REVISION
DESCRIPTION
REVISED
APPLICATION SPECIFICATION FOR
MICRO-LOCK PLUS 2.0 SINGLE ROW
CHANGE NO.
682239
REVISED BY
SOKUMURA01
DATE
2021/02/09
DOC TYPE
DOC TYPE DESCRIPTION
DOC PART
SERIES
REV APPR BY AIDA
DATE
2022/06/30
PS
APPLICATION SPECIFICATION WORD
A03
505570
INITIAL RELEASE
CUSTOMER
DOCUMENT NUMBER
REVISION
SHEET
INITIAL DRWN KUSATO
DATE
2016/04/20
GENERAL MARKET
5055700001
E
14
OF
49
INITIAL APPR
TKANEKO
DATE
2016/04/21
PROCEDURE: 2090580010-ES TEMPLATE: 2090580010-PAS-A4 REVISION: A1
※
If crimping height and width are too large, there is a problem for the terminal insertion.
Please follow the instructed crimping height.
(Please refer to Application Tooling Specification (ATS))
※
If you feel unusual such as hooking during the insertion, please do not continue by force. After confirming
there is no damage of terminal or receptacle housing, it can be inserted again. If the damage is found,
do not use the terminal and receptacle housing.
※
Please use care with the direction of terminal when inserting to receptacle housing.
(Fig.6-2,6-3)
Please be
careful that the terminal is not upside down, not having an angle, or not rotated 5 degrees max against
receptacle housing. These may cause terminal deformation or damage to receptacle housing.
Terminal lance
Fig.6-3 Inappropriate insertion direction
Fig.6-2 Right insertion
direction
Rotated
Having an angle
Upside down direction
〇
×
×
×
Mold lance
Instruction
Good
No Good
No Good
No Good